diff options
author | Chris Paterson <[email protected]> | 2017-12-14 09:08:40 +0000 |
---|---|---|
committer | Simon Horman <[email protected]> | 2017-12-18 12:14:18 +0100 |
commit | e4fdf59bcce3b490bbc7197145bcb9f9d5a18cd3 (patch) | |
tree | c1f3cab8bb1457d7415122b0c37689995fbc201e /tools/perf/scripts/python/call-graph-from-sql.py | |
parent | fcab5651fae4258a993170b7aaf443adbd3d4d84 (diff) |
ARM: dts: r8a7791: Correct critical CPU temperature
The R-Car M2W hardware manual states that Tc = –40°C to +105°C. The
thermal sensor has an accuracy of ±5°C and there can be a temperature
difference of 1 or 2 degrees between Tjmax and the thermal sensor due
to the location of the latter.
This means that 95°C is a safer value to use.
Fixes: cac68a56e34b9810 ("ARM: dts: r8a7791: enable to use thermal-zone")
Signed-off-by: Chris Paterson <[email protected]>
Reviewed-by: Geert Uytterhoeven <[email protected]>
Signed-off-by: Simon Horman <[email protected]>
Diffstat (limited to 'tools/perf/scripts/python/call-graph-from-sql.py')