ARM: dts: r8a7790: Correct critical CPU temperature
The R-Car H2 hardware manual states that Tc = –40°C to +105°C. The thermal sensor has an accuracy of ±5°C and there can be a temperature difference of 1 or 2 degrees between Tjmax and the thermal sensor due to the location of the latter. This means that 95°C is a safer value to use. Fixes: a8b805f3606f7af7 ("ARM: dts: r8a7790: enable to use thermal-zone") Signed-off-by: Chris Paterson <[email protected]> Reviewed-by: Geert Uytterhoeven <[email protected]> Signed-off-by: Simon Horman <[email protected]>