diff options
Diffstat (limited to 'kernel/sched/fair.c')
-rw-r--r-- | kernel/sched/fair.c | 63 |
1 files changed, 60 insertions, 3 deletions
diff --git a/kernel/sched/fair.c b/kernel/sched/fair.c index 0f32acb05055..4c4ea474fdc2 100644 --- a/kernel/sched/fair.c +++ b/kernel/sched/fair.c @@ -8824,16 +8824,73 @@ static unsigned long scale_rt_capacity(int cpu) static void update_cpu_capacity(struct sched_domain *sd, int cpu) { + unsigned long capacity_orig = arch_scale_cpu_capacity(cpu); unsigned long capacity = scale_rt_capacity(cpu); struct sched_group *sdg = sd->groups; + struct rq *rq = cpu_rq(cpu); - cpu_rq(cpu)->cpu_capacity_orig = arch_scale_cpu_capacity(cpu); + rq->cpu_capacity_orig = capacity_orig; if (!capacity) capacity = 1; - cpu_rq(cpu)->cpu_capacity = capacity; - trace_sched_cpu_capacity_tp(cpu_rq(cpu)); + rq->cpu_capacity = capacity; + + /* + * Detect if the performance domain is in capacity inversion state. + * + * Capacity inversion happens when another perf domain with equal or + * lower capacity_orig_of() ends up having higher capacity than this + * domain after subtracting thermal pressure. + * + * We only take into account thermal pressure in this detection as it's + * the only metric that actually results in *real* reduction of + * capacity due to performance points (OPPs) being dropped/become + * unreachable due to thermal throttling. + * + * We assume: + * * That all cpus in a perf domain have the same capacity_orig + * (same uArch). + * * Thermal pressure will impact all cpus in this perf domain + * equally. + */ + if (static_branch_unlikely(&sched_asym_cpucapacity)) { + unsigned long inv_cap = capacity_orig - thermal_load_avg(rq); + struct perf_domain *pd = rcu_dereference(rq->rd->pd); + + rq->cpu_capacity_inverted = 0; + + for (; pd; pd = pd->next) { + struct cpumask *pd_span = perf_domain_span(pd); + unsigned long pd_cap_orig, pd_cap; + + cpu = cpumask_any(pd_span); + pd_cap_orig = arch_scale_cpu_capacity(cpu); + + if (capacity_orig < pd_cap_orig) + continue; + + /* + * handle the case of multiple perf domains have the + * same capacity_orig but one of them is under higher + * thermal pressure. We record it as capacity + * inversion. + */ + if (capacity_orig == pd_cap_orig) { + pd_cap = pd_cap_orig - thermal_load_avg(cpu_rq(cpu)); + + if (pd_cap > inv_cap) { + rq->cpu_capacity_inverted = inv_cap; + break; + } + } else if (pd_cap_orig > inv_cap) { + rq->cpu_capacity_inverted = inv_cap; + break; + } + } + } + + trace_sched_cpu_capacity_tp(rq); sdg->sgc->capacity = capacity; sdg->sgc->min_capacity = capacity; |