commit3fc134a07438055fc93ce1bbacf2702ddd09500c (patch)
treee6892e2516d5dd59d35c2a881591b0b8b79a4231 /tools/perf/scripts
parentd7248f1cc835bd80e936dc5b2d94b149bdd0077d (diff)
mlxsw: core_hwmon: Adjust module label names based on MTCAP sensor counter
Transceiver module temperature sensors are indexed after ASIC and platform sensors. The current label printing method does not take this into account and simply prints the index of the transceiver module sensor. On new systems that have platform sensors this results in incorrect (shifted) transceiver module labels being printed: $ sensors [...] front panel 002: +37.0°C (crit = +70.0°C, emerg = +75.0°C) front panel 003: +47.0°C (crit = +70.0°C, emerg = +75.0°C) [...] Fix by taking the sensor count into account. After the fix: $ sensors [...] front panel 001: +37.0°C (crit = +70.0°C, emerg = +75.0°C) front panel 002: +47.0°C (crit = +70.0°C, emerg = +75.0°C) [...] Fixes: a53779de6a0e ("mlxsw: core: Add QSFP module temperature label attribute to hwmon") Signed-off-by: Vadim Pasternak <[email protected]> Reviewed-by: Ido Schimmel <[email protected]> Signed-off-by: Petr Machata <[email protected]> Signed-off-by: David S. Miller <[email protected]>