diff options
| author | addy ke <[email protected]> | 2015-02-20 10:55:25 +0800 |
|---|---|---|
| committer | Ulf Hansson <[email protected]> | 2015-03-23 14:13:29 +0100 |
| commit | bdb9a90b3d123d9d421dd840c0f7fba1d1dfeba2 (patch) | |
| tree | f5d0e3e4356066bcdeac520b1581bd7e5c8d8352 /tools/perf/scripts/python | |
| parent | 6d53200b51a57f50bc5a98b36bfcdb47483ad61a (diff) | |
mmc: dw_mmc: fix mmc_test by not sending abort for DRTO/EBE errors
The STOP command can terminate a data transfer between a memory card and
mmc controller.
As show in Synopsys DesignWare Cores Mobile Storage Host Databook:
Data timeout and Data end-bit error will terminate further data transfer
by mmc controller. So we should not send abort command to terminate a
data transfer again if we got DRTO and EBE interrupt.
After this patch, all mmc_test cases can pass on RK3288-Pink2 board.
Signed-off-by: Addy Ke <[email protected]>
Reviewed-by: Doug Anderson <[email protected]>
Tested-by: Doug Anderson <[email protected]>
Tested-by: Javier Martinez Canillas <[email protected]>
Signed-off-by: Jaehoon Chung <[email protected]>
Signed-off-by: Ulf Hansson <[email protected]>
Diffstat (limited to 'tools/perf/scripts/python')
0 files changed, 0 insertions, 0 deletions