phy: qcom-qmp-combo: fix sc8180x reset
The SC8180X has two resets but the DP configuration erroneously
described only one.
In case the DP part of the PHY is initialised before the USB part (e.g.
depending on probe order), then only the first reset would be asserted.
Fixes: 1633802cd4ac ("phy: qcom: qmp: Add SC8180x USB/DP combo")
Cc: [email protected] # 5.15
Reviewed-by: Dmitry Baryshkov <[email protected]>
Signed-off-by: Johan Hovold <[email protected]>
Link: https://lore.kernel.org/r/[email protected]
Signed-off-by: Vinod Koul <[email protected]>