mmc: sdhci-esdhc-imx: manually reset MIX_CTRL for usdhc
It's another violation to SDHC spec that software reset on usdhc
does not reset MIX_CTRL register. Have to do it manually, otherwise
the preserving of the register bits (e.g. AC23EN) may cause mmc card
fail to be initialized.
Signed-off-by: Shawn Guo <[email protected]>
Tested-by: Dirk Behme <[email protected]>