diff options
| author | Sujith Manoharan <[email protected]> | 2013-10-07 19:51:57 -0700 |
|---|---|---|
| committer | Kalle Valo <[email protected]> | 2013-10-08 22:10:22 +0300 |
| commit | a24b88b56074424a413acc2d2a517fb82f5e7c2f (patch) | |
| tree | 29426257813d5d99ecac3c25179c988b5bdec782 /tools/perf/scripts/python/syscall-counts-by-pid.py | |
| parent | 0d1a28f241e917d199ad72644edd0d6bb6726577 (diff) | |
ath10k: Fix bug in max. VHT A-MPDU size
For VHT peers, the maximum A-MPDU size has to be calculated
from the VHT capabilities element and not the HT-cap. The formula
is the same, but a higher value is used in VHT, allowing larger
aggregates to be transmitted.
The patch contains a workaround for some Netgear/Linksys APs that
report Rx A-MPDU factor incorrectly.
Tested-by: Kalle Valo <[email protected]>
Signed-off-by: Sujith Manoharan <[email protected]>
Signed-off-by: Michal Kazior <[email protected]>
Signed-off-by: Kalle Valo <[email protected]>
Diffstat (limited to 'tools/perf/scripts/python/syscall-counts-by-pid.py')
0 files changed, 0 insertions, 0 deletions