diff options
author | Ville Syrjälä <[email protected]> | 2016-10-21 16:44:38 +0300 |
---|---|---|
committer | Ville Syrjälä <[email protected]> | 2016-10-26 11:16:34 +0300 |
commit | 1aab956c7b8872fb6976328316bfad62c6e67cf8 (patch) | |
tree | 5b7cacba4bdbf2ee714efe2ecaa925f134aac9ae /tools/perf/scripts/python/net_dropmonitor.py | |
parent | 3299e7e43484a85eeb5c7ec09958bff05c9d0543 (diff) |
drm/i915: Refresh that status of MST capable connectors in ->detect()
Once we've determined that the sink is MST capable we never end up
running through the full detect cycle again, despite getting HPDs.
Fix tht by ripping out the incorrect piece of code responsible.
This got broken when I moved the long HPD handling to the ->detect()
hook, but failed to remove the leftover code.
Cc: Ander Conselvan de Oliveira <[email protected]>
Cc: [email protected]
Cc: Rui Tiago Matos <[email protected]>
Tested-by: Rui Tiago Matos <[email protected]>
Bugzilla: https://bugs.freedesktop.org/show_bug.cgi?id=98323
Cc: Kirill A. Shutemov <[email protected]>
Tested-by: Kirill A. Shutemov <[email protected]>
References: https://bugs.freedesktop.org/show_bug.cgi?id=98306
Fixes: 27d4efc5591a ("drm/i915: Move long hpd handling into the hotplug work")
Signed-off-by: Ville Syrjälä <[email protected]>
Link: http://patchwork.freedesktop.org/patch/msgid/[email protected]
Reviewed-by: Chris Wilson <[email protected]>
Diffstat (limited to 'tools/perf/scripts/python/net_dropmonitor.py')
0 files changed, 0 insertions, 0 deletions