hwmon: (k10temp) Check range scale when CUR_TEMP register is read-write
Spec says, when CUR_TEMP_TJ_SEL == 3 and CUR_TEMP_RANGE_SEL == 0, it should use RangeUnadjusted is 0, which is (CurTmp*0.125 -49) C. The CUR_TEMP register is read-write when CUR_TEMP_TJ_SEL == 3 (bit 17-16). Add the check to detect it. Sensors command's output before the patch. $sensors k10temp-pci-00c3 Adapter: PCI adapter Tctl: +76.6°C <- Wrong value Tccd1: +26.5°C Tccd2: +27.5°C Tccd3: +27.2°C Tccd4: +27.5°C Tccd5: +26.0°C Tccd6: +26.2°C Tccd7: +25.0°C Tccd8: +26.5°C Sensors command's output after the patch. $sensors k10temp-pci-00c3 Adapter: PCI adapter Tctl: +28.8°C <- corrected value Tccd1: +27.5°C Tccd2: +28.5°C Tccd3: +28.5°C Tccd4: +28.5°C Tccd5: +27.0°C Tccd6: +27.5°C Tccd7: +27.0°C Tccd8: +27.5°C Signed-off-by: Babu Moger <[email protected]> Fixes: 1b59788979ac ("hwmon: (k10temp) Add temperature offset for Ryzen 2700X") Link: https://lore.kernel.org/r/[email protected] Cc: [email protected] Signed-off-by: Guenter Roeck <[email protected]>