authorLukas Wunner <[email protected]>2018-10-27 10:36:54 +0200
committerMarc Kleine-Budde <[email protected]>2018-11-09 17:20:08 +0100
commitf164d0204b1156a7e0d8d1622c1a8d25752befec (patch)
tree7516ad963c1b3329f5a34205aed56a91e2dd1b1e /tools/perf/scripts/python/futex-contention.py
parent868b7c0f43e61f227bf3d7f7d6134bb3c67bb0e8 (diff)
can: hi311x: Use level-triggered interrupt
If the hi3110 shares the SPI bus with another traffic-intensive device and packets are received in high volume (by a separate machine sending with "cangen -g 0 -i -x"), reception stops after a few minutes and the counter in /proc/interrupts stops incrementing. Bus state is "active". Bringing the interface down and back up reconvenes the reception. The issue is not observed when the hi3110 is the sole device on the SPI bus. Using a level-triggered interrupt makes the issue go away and lets the hi3110 successfully receive 2 GByte over the course of 5 days while a ks8851 Ethernet chip on the same SPI bus handles 6 GByte of traffic. Unfortunately the hi3110 datasheet is mum on the trigger type. The pin description on page 3 only specifies the polarity (active high): http://www.holtic.com/documents/371-hi-3110_v-rev-kpdf.do Cc: Mathias Duckeck <[email protected]> Cc: Akshay Bhat <[email protected]> Cc: Casey Fitzpatrick <[email protected]> Signed-off-by: Lukas Wunner <[email protected]> Cc: linux-stable <[email protected]> Signed-off-by: Marc Kleine-Budde <[email protected]>