authorIan Abbott <[email protected]>2019-03-19 16:54:42 +0000
committerGreg Kroah-Hartman <[email protected]>2019-03-20 08:25:17 +0100
commit776d25ff5b494be280caba9d297477270462e580 (patch)
treeda16466184040d56f41ce3cfc4d3c29a9a527412 /tools/perf/scripts/python/export-to-sqlite.py
parentfe57d1e113fcaf6af600c4d10168513c05230160 (diff)
staging: comedi: ni_mio_common: use insn->n in ni_calib_insn_read()
The `insn_read` handler for the calibration subdevice (`ni_calib_insn_read()`) currently ignores `insn->n` (the number of samples to read) and assumes a single sample is to be read into `data[0]`. Fortunately, the Comedi core ensures that `data[]` has a length of at least 16, so there is no problem with array bounds. The usual Comedi convention for `insn_read` handlers is to read the same channel `insn->n` times into successive elements of `data[]`, so let's do that. Also, follow the usual Comedi convention and return `insn->n` from the handler to indicate success (although any non-negative value will do). Signed-off-by: Ian Abbott <[email protected]> Signed-off-by: Greg Kroah-Hartman <[email protected]>
Diffstat (limited to 'tools/perf/scripts/python/export-to-sqlite.py')
0 files changed, 0 insertions, 0 deletions