thermal: power_allocator: round the division when divvying up power
In situations where there is an uneven number of cooling devices, the
division of power among them can lead to a milliwatt being dropped on
the floor due to rounding errors. This doesn't sound like a lot, but
some devices only grant the lowest cooling device state for their
maximum power. So for instance, if the granted_power is the maximum
power and all devices are getting their maximum power, one would get
max_power - 1, making it choose cooling device state 1, instead of 0.
Round the division to make the calculation more accurate.
Cc: Zhang Rui <[email protected]>
Cc: Eduardo Valentin <[email protected]>
Signed-off-by: Javi Merino <[email protected]>
Signed-off-by: Eduardo Valentin <[email protected]>