memory: emif: Handle devices which are not rated for >85C
As per JESD209-2E specification for LPDDR2, http://www.jedec.org/standards-documents/results/jesd209-2E Table 73, LPDDR2 memories come in two flavors - Standard and Extended. The Standard types can operate from -25C to +85C However, beyond that and upto +105C can only be supported by Extended types. Unfortunately, it seems there is no info in MR0(device info) or MR[1,2](device feature) for run time detection of this capability as far as seen on the spec. Hence, we provide a custom_config flag to be populated by platforms which have these "extended" type memories. For the "Standard" memories, we need to consider MR4 notifications of temperature triggers >85C as equivalent to thermal shutdown events (equivalent to Spec specified thermal shutdown events for "extended" parts). Reported-by: Richard Woodruff <[email protected]> Signed-off-by: Nishanth Menon <[email protected]> Signed-off-by: Lokesh Vutla <[email protected]> Acked-by: Santosh Shilimkar <[email protected]> Signed-off-by: Greg Kroah-Hartman <[email protected]>