thermal: rcar_gen3_thermal: Read calibration from hardware
In production hardware the calibration values used to convert register
values to temperatures can be read from hardware. While pre-production
hardware still depends on pseudo values hard-coded in the driver.
Add support for reading out calibration values from hardware if it's
fused. The presence of fused calibration is indicated in the THSCP
register.
Signed-off-by: Niklas Söderlund <[email protected]>
Tested-by: Kuninori Morimoto <[email protected]>
Reviewed-by: Geert Uytterhoeven <[email protected]>
Link: https://lore.kernel.org/r/[email protected]
Signed-off-by: Daniel Lezcano <[email protected]>