thermal/drivers/tsens: Allow configuring min and max trips
IPQ8074 and IPQ6018 dont support negative trip temperatures and support
up to 204 degrees C as the max trip temperature.
So, instead of always setting the -40 as min and 120 degrees C as max
allow it to be configured as part of the features.
Signed-off-by: Robert Marko <[email protected]>
Reviewed-by: Bjorn Andersson <[email protected]>
Link: https://lore.kernel.org/r/[email protected]
Signed-off-by: Daniel Lezcano <[email protected]>