diff options
| author | Grazvydas Ignotas <[email protected]> | 2012-01-14 22:50:49 +0200 |
|---|---|---|
| committer | Anton Vorontsov <[email protected]> | 2012-02-01 21:27:28 +0400 |
| commit | 4d4036591b3de279a8c93a3cb010b0bc1264703c (patch) | |
| tree | 2ae895a48407219e41332f93bf8e5949ce9440c9 /tools/perf/scripts/python/Perf-Trace-Util/Context.c | |
| parent | b7aaacf56ac9e0cdb58c3d087fea7084d897c307 (diff) | |
bq27x00_battery: Fix flag register read
When reading flags, bq27x00_read() argument is inverted and causes
reads 2 of bytes for bq27200 and 1 byte for bq27500, while their register
sizes are 1 and 2 bytes respectively. This causes bq27500 upper flag
bits always to be returned as 0, causing full charge state to never be
reported correctly, so fix it.
Cc: Lars-Peter Clausen <[email protected]>
Signed-off-by: Grazvydas Ignotas <[email protected]>
Acked-by: Pali Rohár <[email protected]>
Signed-off-by: Anton Vorontsov <[email protected]>
Diffstat (limited to 'tools/perf/scripts/python/Perf-Trace-Util/Context.c')