Input: ads7846 - fix integer overflow on Rt calculation
In some rare cases the 32 bit Rt value will overflow if z2 and x is max, z1 is minimal value and x_plate_ohms is relatively high (for example 800 ohm). This would happen on some screen age with low pressure. There are two possible fixes: - make Rt 64bit - reorder calculation to avoid overflow The second variant seems to be preferable, since 64 bit calculation on 32 bit system is a bit more expensive. Fixes: ffa458c1bd9b6f653008d450f337602f3d52a646 ("spi: ads7846 driver") Co-developed-by: David Jander <[email protected]> Signed-off-by: David Jander <[email protected]> Signed-off-by: Oleksij Rempel <[email protected]> Link: https://lore.kernel.org/r/[email protected] Signed-off-by: Dmitry Torokhov <[email protected]>