diff options
author | Fabrice Gasnier <[email protected]> | 2019-09-18 16:54:21 +0200 |
---|---|---|
committer | Thierry Reding <[email protected]> | 2019-09-21 03:25:10 +0200 |
commit | c91e3234c6035baf5a79763cb4fcd5d23ce75c2b (patch) | |
tree | ff657840c6b1869f809e4d2b5afc5b7bbeee93bf /lib/string_helpers.c | |
parent | 71523d1812aca61e32e742e87ec064e3d8c615e1 (diff) |
pwm: stm32-lp: Add check in case requested period cannot be achieved
LPTimer can use a 32KHz clock for counting. It depends on clock tree
configuration. In such a case, PWM output frequency range is limited.
Although unlikely, nothing prevents user from requesting a PWM frequency
above counting clock (32KHz for instance):
- This causes (prd - 1) = 0xffff to be written in ARR register later in
the apply() routine.
This results in badly configured PWM period (and also duty_cycle).
Add a check to report an error is such a case.
Signed-off-by: Fabrice Gasnier <[email protected]>
Reviewed-by: Uwe Kleine-König <[email protected]>
Signed-off-by: Thierry Reding <[email protected]>
Diffstat (limited to 'lib/string_helpers.c')
0 files changed, 0 insertions, 0 deletions