commit22087c850e8e56c5959640260ab3fa974556ef96 (patch)
tree66325168dba55de147129099f34c19b01bee3908 /lib/mpi/mpiutil.c
parentb1e18768ef1214c0a8048327918a182cabe09f9d (diff)
iio: cros_ec: set calibscale for 3d MEMS to unit vector
By default, set the calibscale vector to unit vector. When calibrating one axis, the other axis calibrations are sent as well. If left to 0, sensor data from uncalibrated axis are zero'ed out until all axis are calibrated. Fixes: ed1f2e85da79 ("iio: cros_ec: Add calibscale for 3d MEMS ") Signed-off-by: Gwendal Grignou <[email protected]> Signed-off-by: Jonathan Cameron <[email protected]>