diff options
author | Fabio Estevam <[email protected]> | 2015-01-14 11:11:03 -0200 |
---|---|---|
committer | Shawn Guo <[email protected]> | 2015-01-20 15:37:10 +0800 |
commit | 7ecd0bde5bfea524a843ad8fa8cb66ccbce68779 (patch) | |
tree | 23224835657656cc0bc902045941c8ec6e4e19a1 /lib/mpi/mpi-pow.c | |
parent | 7a9f0604bd56936b2b18f49824e0e392dc7878c3 (diff) |
ARM: dts: imx25: Fix PWM "per" clocks
Currently PWM functionality is broken on mx25 due to the wrong assignment of the
PWM "per" clock.
According to Documentation/devicetree/bindings/clock/imx25-clock.txt:
pwm_ipg_per 52
,so update the pwm "per" to use 'pwm_ipg_per' instead of 'per10' clock.
With this change PWM can work fine on mx25.
Cc: <[email protected]>
Reported-by: Carlos Soto <[email protected]>
Signed-off-by: Fabio Estevam <[email protected]>
Signed-off-by: Shawn Guo <[email protected]>
Diffstat (limited to 'lib/mpi/mpi-pow.c')
0 files changed, 0 insertions, 0 deletions