author | Antoine Tenart <[email protected]> | 2019-04-26 18:41:23 +0200 |
---|---|---|
committer | David S. Miller <[email protected]> | 2019-04-29 23:17:21 -0400 |
commit | 7a1d8390d015a13c42b1effa1f22fda0858fe6f9 (patch) | |
tree | 54d7705f781781b46c10e7369dbbe71d3479933d /lib/mpi/mpi-bit.c | |
parent | 88d6272acaaa4bfb03da0a87a8754ec431471680 (diff) |
net: phy: micrel: make sure the factory test bit is cleared
The KSZ8081 PHY has a factory test mode which is set at the de-assertion
of the reset line based on the RXER (KSZ8081RNA/RND) or TXC
(KSZ8081MNX/RNB) pin. If a pull-down is missing, or if the pin has a
pull-up, the factory test mode should be cleared by manually writing a 0
(according to the datasheet). This patch makes sure this factory test
bit is cleared in config_init().
Tested-by: Alexandre Belloni <[email protected]>
Signed-off-by: Antoine Tenart <[email protected]>
Reviewed-by: Andrew Lunn <[email protected]>
Signed-off-by: David S. Miller <[email protected]>
Diffstat (limited to 'lib/mpi/mpi-bit.c')
0 files changed, 0 insertions, 0 deletions