diff options
author | Mitch Williams <[email protected]> | 2015-04-27 14:57:13 -0400 |
---|---|---|
committer | Jeff Kirsher <[email protected]> | 2015-07-14 18:26:42 -0700 |
commit | e995163cdcf9b70c7840a8d6a7ea7c0ce81c761b (patch) | |
tree | dedf61d8af67dac9567cb37e22c343cb87976a72 /lib/memory-notifier-error-inject.c | |
parent | cb2f65bc0c64015e8fa45fe1065ad241bf31a994 (diff) |
i40e: correctly program filters for VFs
MAC filters for VFs were being programmed with 0 for the VLAN value when
there was no VLAN assigned. This is incorrect and actually assigns the
VF to VLAN 0. Instead, we must use -1 to indicate that no VLAN is in
use. This change programs the filters correctly and gets rid of a bogus
error message when setting a port VLAN on an active VF.
Change-ID: Ica9a9906d768405377ff3308e27f7d0b5b2ea96e
Signed-off-by: Mitch Williams <[email protected]>
Tested-by: Jim Young <[email protected]>
Signed-off-by: Jeff Kirsher <[email protected]>
Diffstat (limited to 'lib/memory-notifier-error-inject.c')
0 files changed, 0 insertions, 0 deletions