diff options
author | Ewan D. Milne <emilne@redhat.com> | 2023-11-27 15:56:57 -0500 |
---|---|---|
committer | Keith Busch <kbusch@kernel.org> | 2023-11-27 14:00:55 -0800 |
commit | d8b90d600aff181936457f032d116dbd8534db06 (patch) | |
tree | c43e7d9e57f5ea053c7e3c1ef4f2f175325bb0d7 /lib/crypto/mpi/mpi-sub-ui.c | |
parent | e3139cef8257fcab1725441e2fd5fd0ccb5481b1 (diff) |
nvme: check for valid nvme_identify_ns() before using it
When scanning namespaces, it is possible to get valid data from the first
call to nvme_identify_ns() in nvme_alloc_ns(), but not from the second
call in nvme_update_ns_info_block(). In particular, if the NSID becomes
inactive between the two commands, a storage device may return a buffer
filled with zero as per 4.1.5.1. In this case, we can get a kernel crash
due to a divide-by-zero in blk_stack_limits() because ns->lba_shift will
be set to zero.
PID: 326 TASK: ffff95fec3cd8000 CPU: 29 COMMAND: "kworker/u98:10"
#0 [ffffad8f8702f9e0] machine_kexec at ffffffff91c76ec7
#1 [ffffad8f8702fa38] __crash_kexec at ffffffff91dea4fa
#2 [ffffad8f8702faf8] crash_kexec at ffffffff91deb788
#3 [ffffad8f8702fb00] oops_end at ffffffff91c2e4bb
#4 [ffffad8f8702fb20] do_trap at ffffffff91c2a4ce
#5 [ffffad8f8702fb70] do_error_trap at ffffffff91c2a595
#6 [ffffad8f8702fbb0] exc_divide_error at ffffffff928506e6
#7 [ffffad8f8702fbd0] asm_exc_divide_error at ffffffff92a00926
[exception RIP: blk_stack_limits+434]
RIP: ffffffff92191872 RSP: ffffad8f8702fc80 RFLAGS: 00010246
RAX: 0000000000000000 RBX: ffff95efa0c91800 RCX: 0000000000000001
RDX: 0000000000000000 RSI: 0000000000000001 RDI: 0000000000000001
RBP: 00000000ffffffff R8: ffff95fec7df35a8 R9: 0000000000000000
R10: 0000000000000000 R11: 0000000000000001 R12: 0000000000000000
R13: 0000000000000000 R14: 0000000000000000 R15: ffff95fed33c09a8
ORIG_RAX: ffffffffffffffff CS: 0010 SS: 0018
#8 [ffffad8f8702fce0] nvme_update_ns_info_block at ffffffffc06d3533 [nvme_core]
#9 [ffffad8f8702fd18] nvme_scan_ns at ffffffffc06d6fa7 [nvme_core]
This happened when the check for valid data was moved out of nvme_identify_ns()
into one of the callers. Fix this by checking in both callers.
Link: https://bugzilla.kernel.org/show_bug.cgi?id=218186
Fixes: 0dd6fff2aad4 ("nvme: bring back auto-removal of deleted namespaces during sequential scan")
Cc: stable@vger.kernel.org
Signed-off-by: Ewan D. Milne <emilne@redhat.com>
Signed-off-by: Keith Busch <kbusch@kernel.org>
Diffstat (limited to 'lib/crypto/mpi/mpi-sub-ui.c')
0 files changed, 0 insertions, 0 deletions