aboutsummaryrefslogtreecommitdiff
path: root/kernel/bpf/arraymap.c
diff options
context:
space:
mode:
authorVasileios Amoiridis <vassilisamir@gmail.com>2024-06-06 23:22:53 +0200
committerJonathan Cameron <Jonathan.Cameron@huawei.com>2024-06-09 11:57:32 +0100
commitae1f7b93b52095be6776d0f34957b4f35dda44d9 (patch)
tree1edac129fda612fd29f23ed994eb2c653e4cc374 /kernel/bpf/arraymap.c
parent9547d6a4c65e975e40e203900322342ef7379c52 (diff)
iio: chemical: bme680: Fix pressure value output
The IIO standard units are measured in kPa while the driver is using hPa. Apart from checking the userspace value itself, it is mentioned also in the Bosch API [1] that the pressure value is in Pascal. [1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L742 Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor") Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com> Link: https://lore.kernel.org/r/20240606212313.207550-2-vassilisamir@gmail.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'kernel/bpf/arraymap.c')
0 files changed, 0 insertions, 0 deletions