diff options
| author | James Morse <[email protected]> | 2024-02-13 18:44:19 +0000 |
|---|---|---|
| committer | Borislav Petkov (AMD) <[email protected]> | 2024-02-16 19:18:31 +0100 |
| commit | 40fc735b78f0c81cea7d1c511cfd83892cb4d679 (patch) | |
| tree | 2c4517f6c762585ff8b944999241f3ff5f645965 /include/linux | |
| parent | 311639e9512bb3af2abae32be9322b8a9b30eaa1 (diff) | |
x86/resctrl: Track the closid with the rmid
x86's RMID are independent of the CLOSID. An RMID can be allocated,
used and freed without considering the CLOSID.
MPAM's equivalent feature is PMG, which is not an independent number,
it extends the CLOSID/PARTID space. For MPAM, only PMG-bits worth of
'RMID' can be allocated for a single CLOSID.
i.e. if there is 1 bit of PMG space, then each CLOSID can have two
monitor groups.
To allow resctrl to disambiguate RMID values for different CLOSID,
everything in resctrl that keeps an RMID value needs to know the CLOSID
too. This will always be ignored on x86.
Signed-off-by: James Morse <[email protected]>
Signed-off-by: Borislav Petkov (AMD) <[email protected]>
Reviewed-by: Shaopeng Tan <[email protected]>
Reviewed-by: Xin Hao <[email protected]>
Reviewed-by: Reinette Chatre <[email protected]>
Tested-by: Shaopeng Tan <[email protected]>
Tested-by: Peter Newman <[email protected]>
Tested-by: Babu Moger <[email protected]>
Tested-by: Carl Worth <[email protected]> # arm64
Link: https://lore.kernel.org/r/[email protected]
Signed-off-by: Borislav Petkov (AMD) <[email protected]>
Diffstat (limited to 'include/linux')
| -rw-r--r-- | include/linux/resctrl.h | 16 |
1 files changed, 14 insertions, 2 deletions
diff --git a/include/linux/resctrl.h b/include/linux/resctrl.h index 66942d7fba7f..bd4ec22b5a96 100644 --- a/include/linux/resctrl.h +++ b/include/linux/resctrl.h @@ -6,6 +6,10 @@ #include <linux/list.h> #include <linux/pid.h> +/* CLOSID, RMID value used by the default control group */ +#define RESCTRL_RESERVED_CLOSID 0 +#define RESCTRL_RESERVED_RMID 0 + #ifdef CONFIG_PROC_CPU_RESCTRL int proc_resctrl_show(struct seq_file *m, @@ -225,6 +229,9 @@ void resctrl_offline_domain(struct rdt_resource *r, struct rdt_domain *d); * for this resource and domain. * @r: resource that the counter should be read from. * @d: domain that the counter should be read from. + * @closid: closid that matches the rmid. Depending on the architecture, the + * counter may match traffic of both @closid and @rmid, or @rmid + * only. * @rmid: rmid of the counter to read. * @eventid: eventid to read, e.g. L3 occupancy. * @val: result of the counter read in bytes. @@ -235,20 +242,25 @@ void resctrl_offline_domain(struct rdt_resource *r, struct rdt_domain *d); * 0 on success, or -EIO, -EINVAL etc on error. */ int resctrl_arch_rmid_read(struct rdt_resource *r, struct rdt_domain *d, - u32 rmid, enum resctrl_event_id eventid, u64 *val); + u32 closid, u32 rmid, enum resctrl_event_id eventid, + u64 *val); + /** * resctrl_arch_reset_rmid() - Reset any private state associated with rmid * and eventid. * @r: The domain's resource. * @d: The rmid's domain. + * @closid: closid that matches the rmid. Depending on the architecture, the + * counter may match traffic of both @closid and @rmid, or @rmid only. * @rmid: The rmid whose counter values should be reset. * @eventid: The eventid whose counter values should be reset. * * This can be called from any CPU. */ void resctrl_arch_reset_rmid(struct rdt_resource *r, struct rdt_domain *d, - u32 rmid, enum resctrl_event_id eventid); + u32 closid, u32 rmid, + enum resctrl_event_id eventid); /** * resctrl_arch_reset_rmid_all() - Reset all private state associated with |