diff options
author | Carlos Song <[email protected]> | 2023-01-18 15:42:27 +0800 |
---|---|---|
committer | Jonathan Cameron <[email protected]> | 2023-01-21 18:15:19 +0000 |
commit | 2acd031347f645871959a799238a7caf6803aa18 (patch) | |
tree | cc8a0e35ba2e5570a2ae50a007978b524ff545f1 /fs/jbd2/commit.c | |
parent | ff5e2cd92ffda9a25ffa2cbdb3a0cf17650172a6 (diff) |
iio: imu: fxos8700: fix MAGN sensor scale and unit
+/-1200uT is a MAGN sensor full measurement range. Magnetometer scale
is the magnetic sensitivity parameter. It is referenced as 0.1uT
according to datasheet and magnetometer channel unit is Gauss in
sysfs-bus-iio documentation. Gauss and uTesla unit conversion
relationship as follows: 0.1uT = 0.001Gs.
Set magnetometer scale and available magnetometer scale as fixed 0.001Gs.
Fixes: 84e5ddd5c46e ("iio: imu: Add support for the FXOS8700 IMU")
Signed-off-by: Carlos Song <[email protected]>
Link: https://lore.kernel.org/r/[email protected]
Cc: <[email protected]>
Signed-off-by: Jonathan Cameron <[email protected]>
Diffstat (limited to 'fs/jbd2/commit.c')
0 files changed, 0 insertions, 0 deletions