diff options
author | K. Y. Srinivasan <[email protected]> | 2016-01-27 18:22:44 -0800 |
---|---|---|
committer | Martin K. Petersen <[email protected]> | 2016-01-28 22:25:36 -0500 |
commit | d791a8c60e9cbd1c4fecbc5c86ff59c7ffe137e8 (patch) | |
tree | ab2180748dc7b685aff22c0816e35631ac5f4106 | |
parent | 0f28ede906a8ad44158a6ef9471a5a412343cced (diff) |
storvsc: Install the storvsc specific timeout handler for FC devices
The default timeout routine used for FC transport is not suitable for FC
devices managed by storvsc since FC devices managed by storvsc driver do
not have an rport associated with them. Use the time out handler used
for SCSI devices for FC devices as well.
Signed-off-by: K. Y. Srinivasan <[email protected]>
Reviewed-by: Alex Ng <[email protected]>
Tested-by: Vivek Yadav <[email protected]>
Reviewed-by: Johannes Thumshirn <[email protected]>
Signed-off-by: Martin K. Petersen <[email protected]>
-rw-r--r-- | drivers/scsi/storvsc_drv.c | 6 |
1 files changed, 6 insertions, 0 deletions
diff --git a/drivers/scsi/storvsc_drv.c b/drivers/scsi/storvsc_drv.c index 41c115c230d9..622f64a98a9e 100644 --- a/drivers/scsi/storvsc_drv.c +++ b/drivers/scsi/storvsc_drv.c @@ -42,6 +42,7 @@ #include <scsi/scsi_devinfo.h> #include <scsi/scsi_dbg.h> #include <scsi/scsi_transport_fc.h> +#include <scsi/scsi_transport.h> /* * All wire protocol details (storage protocol between the guest and the host) @@ -1770,6 +1771,11 @@ static int __init storvsc_drv_init(void) fc_transport_template = fc_attach_transport(&fc_transport_functions); if (!fc_transport_template) return -ENODEV; + + /* + * Install Hyper-V specific timeout handler. + */ + fc_transport_template->eh_timed_out = storvsc_eh_timed_out; #endif ret = vmbus_driver_register(&storvsc_drv); |