diff options
author | Joonwoo Park <[email protected]> | 2016-09-19 14:46:54 -0700 |
---|---|---|
committer | Mark Brown <[email protected]> | 2016-09-24 19:36:41 +0100 |
commit | 577766175c40d4f425be47b9e70d80238e53f996 (patch) | |
tree | 27085b73567bfb76e2e2ff56299b6ba44766a2ae | |
parent | 29b4817d4018df78086157ea3a55c1d9424a7cfc (diff) |
regulator: core: don't return error with inadequate reason
drms_uA_update() always returns failure when it cannot find regulator's
input voltage. But if hardware supports load configuration with
ops->set_load() and the input regulator isn't specified with valid reason
such as the input regulator is battery, not finding input voltage is
normal so such case should not return with an error.
Avoid such inadequate error return by checking input/output voltages
only when drms_uA_update() is about to configure load with enum based
ops->set_mode().
Cc: Liam Girdwood <[email protected]>
Cc: Mark Brown <[email protected]>
Cc: Bjorn Andersson <[email protected]>
Cc: [email protected]
Signed-off-by: Joonwoo Park <[email protected]>
Signed-off-by: Mark Brown <[email protected]>
-rw-r--r-- | drivers/regulator/core.c | 36 |
1 files changed, 18 insertions, 18 deletions
diff --git a/drivers/regulator/core.c b/drivers/regulator/core.c index db320e8fa865..bafcdff42872 100644 --- a/drivers/regulator/core.c +++ b/drivers/regulator/core.c @@ -679,24 +679,6 @@ static int drms_uA_update(struct regulator_dev *rdev) !rdev->desc->ops->set_load) return -EINVAL; - /* get output voltage */ - output_uV = _regulator_get_voltage(rdev); - if (output_uV <= 0) { - rdev_err(rdev, "invalid output voltage found\n"); - return -EINVAL; - } - - /* get input voltage */ - input_uV = 0; - if (rdev->supply) - input_uV = regulator_get_voltage(rdev->supply); - if (input_uV <= 0) - input_uV = rdev->constraints->input_uV; - if (input_uV <= 0) { - rdev_err(rdev, "invalid input voltage found\n"); - return -EINVAL; - } - /* calc total requested load */ list_for_each_entry(sibling, &rdev->consumer_list, list) current_uA += sibling->uA_load; @@ -709,6 +691,24 @@ static int drms_uA_update(struct regulator_dev *rdev) if (err < 0) rdev_err(rdev, "failed to set load %d\n", current_uA); } else { + /* get output voltage */ + output_uV = _regulator_get_voltage(rdev); + if (output_uV <= 0) { + rdev_err(rdev, "invalid output voltage found\n"); + return -EINVAL; + } + + /* get input voltage */ + input_uV = 0; + if (rdev->supply) + input_uV = regulator_get_voltage(rdev->supply); + if (input_uV <= 0) + input_uV = rdev->constraints->input_uV; + if (input_uV <= 0) { + rdev_err(rdev, "invalid input voltage found\n"); + return -EINVAL; + } + /* now get the optimum mode for our new total regulator load */ mode = rdev->desc->ops->get_optimum_mode(rdev, input_uV, output_uV, current_uA); |