arm: dts: add omap4 CPU thermal data
This patch changes a dtsi file to contain the thermal data
for MPU domain on OMAP4 and later SoCs. This data will
enable the passive cooling with CPUfreq cooling device
at 100C and the system will do a thermal shutdown at 125C.
This thermal data can be reused across TI SoC devices.
Cc: "BenoƮt Cousson" <[email protected]>
Cc: Tony Lindgren <[email protected]>
Cc: Rob Herring <[email protected]>
Cc: Pawel Moll <[email protected]>
Cc: Mark Rutland <[email protected]>
Cc: Stephen Warren <[email protected]>
Cc: Ian Campbell <[email protected]>
Cc: Russell King <[email protected]>
Cc: [email protected]
Cc: [email protected]
Cc: [email protected]
Cc: [email protected]
Signed-off-by: Eduardo Valentin <[email protected]>
-rw-r--r-- | arch/arm/boot/dts/omap4-cpu-thermal.dtsi | 41 |
1 files changed, 41 insertions, 0 deletions
diff --git a/arch/arm/boot/dts/omap4-cpu-thermal.dtsi b/arch/arm/boot/dts/omap4-cpu-thermal.dtsi new file mode 100644 index 000000000000..cb9458feb2e3 --- /dev/null +++ b/arch/arm/boot/dts/omap4-cpu-thermal.dtsi @@ -0,0 +1,41 @@ +/* + * Device Tree Source for OMAP4/5 SoC CPU thermal + * + * Copyright (C) 2013 Texas Instruments Incorporated - http://www.ti.com/ + * Contact: Eduardo Valentin <[email protected]> + * + * This file is licensed under the terms of the GNU General Public License + * version 2. This program is licensed "as is" without any warranty of any + * kind, whether express or implied. + */ + +#include <dt-bindings/thermal/thermal.h> + +cpu_thermal: cpu_thermal { + polling-delay-passive = <250>; /* milliseconds */ + polling-delay = <1000>; /* milliseconds */ + + /* sensor ID */ + thermal-sensors = <&bandgap 0>; + + trips { + cpu_alert0: cpu_alert { + temperature = <100000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "passive"; + }; + cpu_crit: cpu_crit { + temperature = <125000>; /* millicelsius */ + hysteresis = <2000>; /* millicelsius */ + type = "critical"; + }; + }; + + cooling-maps { + map0 { + trip = <&cpu_alert0>; + cooling-device = + <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>; + }; + }; +}; |