authorChristophe JAILLET <christophe.jaillet@wanadoo.fr>2024-06-23 10:04:45 +0200
committerSebastian Reichel <sebastian.reichel@collabora.com>2024-06-26 17:32:00 +0200
commit0b209ec85b2b73c38a09ba71dc05fbe4aee7be67 (patch)
treeafb649c6ef5032b8106ff65d7ca02fc05bb77143
parent5d55721d6e24c8e99cc86ee1fcb90d776ef47964 (diff)
power: supply: samsung-sdi-battery: Constify struct power_supply_maintenance_charge_table
'struct power_supply_maintenance_charge_table' is not modified in this driver. Constifying this structure moves some data to a read-only section, so increase overall security. In order to do it, some code also needs to be adjusted to this new const qualifier. On a x86_64, with allmodconfig: Before: ====== $ size drivers/power/supply/samsung-sdi-battery.o text data bss dec hex filename 4055 4584 0 8639 21bf drivers/power/supply/samsung-sdi-battery.o After: ===== $ size drivers/power/supply/samsung-sdi-battery.o text data bss dec hex filename 4087 4552 0 8639 21bf drivers/power/supply/samsung-sdi-battery.o Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr> Link: https://lore.kernel.org/r/6caafd0ac2556a40405273b1a4badc508ea8e9b0.1719125040.git.christophe.jaillet@wanadoo.fr Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
-rw-r--r--drivers/power/supply/ab8500_chargalg.c2
-rw-r--r--drivers/power/supply/power_supply_core.c2
-rw-r--r--drivers/power/supply/samsung-sdi-battery.c2
-rw-r--r--include/linux/power_supply.h6
4 files changed, 6 insertions, 6 deletions
diff --git a/drivers/power/supply/ab8500_chargalg.c b/drivers/power/supply/ab8500_chargalg.c
index 55ab7a28056e..854491ad3ecd 100644
--- a/drivers/power/supply/ab8500_chargalg.c
+++ b/drivers/power/supply/ab8500_chargalg.c
@@ -1225,8 +1225,8 @@ static bool ab8500_chargalg_time_to_restart(struct ab8500_chargalg *di)
*/
static void ab8500_chargalg_algorithm(struct ab8500_chargalg *di)
{
+ const struct power_supply_maintenance_charge_table *mt;
struct power_supply_battery_info *bi = di->bm->bi;
- struct power_supply_maintenance_charge_table *mt;
int charger_status;
int ret;
diff --git a/drivers/power/supply/power_supply_core.c b/drivers/power/supply/power_supply_core.c
index 022d0e4bf621..8f6025acd10a 100644
--- a/drivers/power/supply/power_supply_core.c
+++ b/drivers/power/supply/power_supply_core.c
@@ -1072,7 +1072,7 @@ int power_supply_vbat2ri(struct power_supply_battery_info *info,
}
EXPORT_SYMBOL_GPL(power_supply_vbat2ri);
-struct power_supply_maintenance_charge_table *
+const struct power_supply_maintenance_charge_table *
power_supply_get_maintenance_charging_setting(struct power_supply_battery_info *info,
int index)
{
diff --git a/drivers/power/supply/samsung-sdi-battery.c b/drivers/power/supply/samsung-sdi-battery.c
index 725fbe09379e..b63fd2758c2f 100644
--- a/drivers/power/supply/samsung-sdi-battery.c
+++ b/drivers/power/supply/samsung-sdi-battery.c
@@ -613,7 +613,7 @@ static struct power_supply_battery_ocv_table samsung_ocv_cap_eb585157lu[] = {
{ .ocv = 3300000, .capacity = 0},
};
-static struct power_supply_maintenance_charge_table samsung_maint_charge_table[] = {
+static const struct power_supply_maintenance_charge_table samsung_maint_charge_table[] = {
{
/* Maintenance charging phase A, 60 hours */
.charge_current_max_ua = 600000,
diff --git a/include/linux/power_supply.h b/include/linux/power_supply.h
index 5061eeecf62e..72dc7e45c90c 100644
--- a/include/linux/power_supply.h
+++ b/include/linux/power_supply.h
@@ -736,7 +736,7 @@ struct power_supply_battery_info {
int overvoltage_limit_uv;
int constant_charge_current_max_ua;
int constant_charge_voltage_max_uv;
- struct power_supply_maintenance_charge_table *maintenance_charge;
+ const struct power_supply_maintenance_charge_table *maintenance_charge;
int maintenance_charge_size;
int alert_low_temp_charge_current_ua;
int alert_low_temp_charge_voltage_uv;
@@ -810,7 +810,7 @@ power_supply_temp2resist_simple(struct power_supply_resistance_temp_table *table
int table_len, int temp);
extern int power_supply_vbat2ri(struct power_supply_battery_info *info,
int vbat_uv, bool charging);
-extern struct power_supply_maintenance_charge_table *
+extern const struct power_supply_maintenance_charge_table *
power_supply_get_maintenance_charging_setting(struct power_supply_battery_info *info, int index);
extern bool power_supply_battery_bti_in_range(struct power_supply_battery_info *info,
int resistance);
@@ -824,7 +824,7 @@ extern int power_supply_set_battery_charged(struct power_supply *psy);
static inline bool
power_supply_supports_maintenance_charging(struct power_supply_battery_info *info)
{
- struct power_supply_maintenance_charge_table *mt;
+ const struct power_supply_maintenance_charge_table *mt;
mt = power_supply_get_maintenance_charging_setting(info, 0);