| Age | Commit message (Collapse) | Author | Files | Lines |
|
The Siemens IOT2040 comes with a RS485 interface that allows to enable
or disable bus termination via software. Add a bit to the flags field of
serial_rs485 that applications can set in order to request this feature
from the hardware. This seems generic enough to add it for everyone.
Existing driver will simply ignore it when set.
Signed-off-by: Sascha Weisenberger <[email protected]>
Signed-off-by: Jan Kiszka <[email protected]>
Signed-off-by: Greg Kroah-Hartman <[email protected]>
|
|
Currently, 8-bit (MMIO) and 32-bit (MMIO32) register interfaces are
supported for the 8250 console, but the 16-bit (MMIO16) is not.
The 8250 UART device on my board is connected to a 16-bit bus and
my main motivation is to use earlycon with it.
(Refer to arch/arm/boot/dts/uniphier-support-card.dtsi)
Signed-off-by: Masahiro Yamada <[email protected]>
Reviewed-by: Peter Hurley <[email protected]>
Signed-off-by: Greg Kroah-Hartman <[email protected]>
|
|
ioctl(TIOCGSERIAL|TIOCSSERIAL) report and can change the port->iotype.
UART drivers use the UPIO_* definitions, but the uapi header defines
parallel values and userspace uses these parallel values for ioctls;
thus the userspace values are definitive.
Define UPIO_* iotypes in terms of the uapi defines, SERIAL_IO_*;
extend the uapi defines to include all values in use by the serial
core.
Signed-off-by: Peter Hurley <[email protected]>
Signed-off-by: Greg Kroah-Hartman <[email protected]>
|
|
Signed-off-by: David Howells <[email protected]>
Acked-by: Arnd Bergmann <[email protected]>
Acked-by: Thomas Gleixner <[email protected]>
Acked-by: Michael Kerrisk <[email protected]>
Acked-by: Paul E. McKenney <[email protected]>
Acked-by: Dave Jones <[email protected]>
|