aboutsummaryrefslogtreecommitdiff
path: root/drivers/net/ethernet/intel/i40e
AgeCommit message (Collapse)AuthorFilesLines
2017-03-20i40e: rework exit flow of i40e_add_fdir_ethtoolJacob Keller1-4/+11
Refactor the exit flow of the i40e_add_fdir_ethtool function. Move the input_label to the end of the function, removing the dependency on having a non-zero return value. Add a comment explaining why it is ok not to free the fdir data structure, because the structure is now stored in the fdir_filter_list. Change-Id: I723342181d59cd0c9f3b31140c37961ba37bb242 Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-20i40e: don't use arrays for (src|dst)_ipJacob Keller3-14/+14
The code originally included src_ip and dst_ip with enough space to support ipv6 filters. However, no actual support for ipv6 filters has been implemented. Thus, remove the arrays and just use __be32 values. Should ipv6 support be added in the future, we can replace these with a union that has sizes for both values. Change-Id: I1bc04032244a80eb6ebc8a4e6c723a4a665c1dd5 Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-20i40e: send correct port number to AdminQ when enabling UDP tunnelsJacob Keller2-10/+10
The firmware expects the port numbers for offloaded UDP tunnels in Little Endian format. We accidentally sent the value in Big Endian format which obviously will cause the wrong port number to be put into the UDP tunnels list. This results in VxLAN and Geneve tunnel Rx offloads being essentially disabled, unless the port number happens to be identical after byte swapping. Note that i40e_aq_add_udp_tunnel() will byteswap the parameter from host order into Little Endian so we don't need worry about passing strictly a __le16 value to the command. This patch essentially reverts b3f5c7bc88ba ("i40e: Fix for extra byte swap in tunnel setup", 2016-08-24), but in a way that makes the result much more clear to the reader. Fixes: b3f5c7bc88ba ("i40e: Fix for extra byte swap in tunnel setup", 2016-08-24) Signed-off-by: Jacob Keller <[email protected]> Reviewed-by: Williams, Mitch A <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-17i40e: use new api ethtool_{get|set}_link_ksettingsPhilippe Reynes1-111/+153
The ethtool api {get|set}_settings is deprecated. We move this driver to new api {get|set}_link_ksettings. As I don't have the hardware, I'd be very pleased if someone may test this patch. Signed-off-by: Philippe Reynes <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-15mqprio: Modify mqprio to pass user parameters via ndo_setup_tc.Amritha Nambiar1-2/+5
The configurable priority to traffic class mapping and the user specified queue ranges are used to configure the traffic class, overriding the hardware defaults when the 'hw' option is set to 0. However, when the 'hw' option is non-zero, the hardware QOS defaults are used. This patch makes it so that we can pass the data the user provided to ndo_setup_tc. This allows us to pull in the queue configuration if the user requested it as well as any additional hardware offload type requested by using a value other than 1 for the hw value. Finally it also provides a means for the device driver to return the level supported for the offload type via the qopt->hw value. Previously we were just always assuming the value to be 1, in the future values beyond just 1 may be supported. Signed-off-by: Amritha Nambiar <[email protected]> Signed-off-by: Alexander Duyck <[email protected]> Signed-off-by: David S. Miller <[email protected]>
2017-03-15i40e: rename auto_disable_flags to hw_disabled_flagsHarshitha Ramamurthy4-31/+35
A previous commit introduced a field that tracks the features that are disabled due to HW resource limitations as opposed to the featured disabled by the user. This patch changes the name of the field to make it more readable since it might get confusing when looking at code containing both the flags field and the auto_disable_features field together. Change-ID: Idcc9888659698f6fe3ccff17c8c3f09b5026f708 Signed-off-by: Harshitha Ramamurthy <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-15i40e/i40evf: Change version from 1.6.27 to 2.1.7Bimmy Pujari1-3/+3
Signed-off-by: Bimmy Pujari <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-15i40e: Allow untrusted VFs to have more filtersMitch Williams1-1/+1
Our original filter limit of 8 was based on behavior that we saw from Linux VMs. Now we're running Other Operating Systems under KVM and we see that they commonly use more MAC filters. Since it seems weird to require people to enable trusted VFs just to boot their OS, bump the number of filters allowed by default. Change-ID: I76b2dcb2ad6017e39231ad3096c3fb6f065eef5e Signed-off-by: Mitch Williams <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-15i40e/i40evf: Add support for mapping pages with DMA attributesAlexander Duyck2-5/+29
This patch adds support for DMA_ATTR_SKIP_CPU_SYNC and DMA_ATTR_WEAK_ORDERING. By enabling both of these for the Rx path we are able to see performance improvements on architectures that implement either one due to the fact that page mapping and unmapping only has to sync what is actually being used instead of the entire buffer. In addition by enabling the weak ordering attribute enables a performance improvement for architectures that can associate a memory ordering with a DMA buffer such as Sparc. Change-ID: If176824e8231c5b24b8a5d55b339a6026738fc75 Signed-off-by: Alexander Duyck <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-15i40e: Clarify steps in MAC/VLAN filters initialization routineFilip Sadowski1-4/+4
This patch clarifies the reason for removal of automatically firmware-generated filter and explicit addition of filter which accepts frames with any VLAN id. Change-ID: Iabf180b6d61c4d8a36d3bcf8457c377a6f2aca0e Signed-off-by: Filip Sadowski <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-15i40e: fix RSS queues only operating on PF0Lihong Yang2-12/+5
This patch fixes the issue that RSS offloading only works on PF0 by using the direct register writing of the hash keys for the VFs instead of using the admin queue command to do so. Change-ID: Ia02cda7dbaa23def342e8786097a2c03db6f580b Signed-off-by: Lihong Yang <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-15i40e: fix ethtool to get EEPROM data from X722 interfaceLihong Yang1-0/+5
Currently ethtool -e will error out with a X722 interface as its EEPROM has a scope limit at offset 0x5B9FFF. This patch fixes the issue by setting the EEPROM length to the scope limit to avoid NVM read failure beyond that. Change-ID: I0b7d4dd6c7f2a57cace438af5dffa0f44c229372 Signed-off-by: Lihong Yang <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-15i40e: don't add more vectors to num_lan_msix than number of CPUsJacob Keller1-3/+27
This is a solution to avoid adding too many queues to num_lan_msix. A recent refactor of queue pairs accidentally added all remaining vectors to the num_lan_msix which can have adverse performance issues, due to enabling more queues than the number of CPU cores. This patch removes the old calculation, and replaces it with a simple algorithm. 1) add queue pairs up to num_online_cpus(), but capped at half of total vectors 2) then add alternative features such as flow directory and similar 3) finally, add the remaining vectors back to queue pairs, but capped such that the total number of queue pairs does not exceed num_online_cpus(). Change-ID: I668abf67d5011a1248866daba8885f4ff00cb8d9 Signed-off-by: Jacob Keller <[email protected]> Signed-off-by: Harshitha Ramamurthy <[email protected]> Signed-off-by: Carolyn Wyborny <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-15i40e: KISS the client interfaceMitch Williams5-328/+179
(KISS is Keep It Simple, Stupid. Or is it?) The client interface vastly overengineered for what it needs to do. It was originally designed to support multiple clients on multiple netdevs, possibly even with multiple drivers. None of this happened, and now we know that there will only ever be one client for i40e (i40iw) and one for i40evf (i40iwvf). So, time for some KISS. Since i40e and i40evf are a Dynasty, we'll simplify this one to match the VF interface. First, be a Destroyer and remove all of the lists and locks required to support multiple clients. Keep one static around to keep track of one client, and track the client instances for each netdev in the driver's pf (or adapter) struct. Now it's Almost Human. Since we already know the client type is iWarp, get rid of any checks for this. Same for VSI type - it's always going to be the same type, so it's just a Parasite. While we're at it, fix up some comments. This makes the function headers actually match the functions. These changes reduce code complexity, simplify maintenance, squash some lurking timing bugs, and allow us to Rock and Roll All Nite. Change-ID: I1ea79948ad73b8685272451440a34507f9a9012e Signed-off-by: Mitch Williams <[email protected]> Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-14i40e: fix up recent proxy and wol bits for X722_SUPPORTShannon Nelson1-1/+64
Some opcodes added & reordered to be in numerical order with the rest of the opcodes. This patch adds admin queue structs to support Wake on LAN feature for X722. Signed-off-by: Shannon Nelson <[email protected]> Signed-off-by: Carolyn Wyborny <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-03-14i40e: Acquire NVM lock before reads on all devicesAaron Salter1-6/+6
Acquire NVM lock before reads on all devices. Previously, locks were only used for X722 and later. Fixes an issue where simultaneous X710 NVM accesses were interfering with each other. Change-ID: If570bb7acf958cef58725ec2a2011cead6f80638 Signed-off-by: Aaron Salter <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-27scripts/spelling.txt: add "varible" pattern and fix typo instancesMasahiro Yamada1-3/+1
Fix typos and add the following to the scripts/spelling.txt: varible||variable While we are here, tidy up the comment blocks that fit in a single line for drivers/net/ethernet/intel/i40e/i40e_virtchnl_pf.c and net/sctp/transport.c. Link: http://lkml.kernel.org/r/[email protected] Signed-off-by: Masahiro Yamada <[email protected]> Signed-off-by: Andrew Morton <[email protected]> Signed-off-by: Linus Torvalds <[email protected]>
2017-02-18i40e: Invoke softirqs after napi_rescheduleBenjamin Poirier1-0/+2
The following message is logged from time to time when using i40e: NOHZ: local_softirq_pending 08 i40e may schedule napi from a workqueue. Afterwards, softirqs are not run in a deterministic time frame. The problem is the same as what was described in commit ec13ee80145c ("virtio_net: invoke softirqs after __napi_schedule") and this patch applies the same fix to i40e. Signed-off-by: Benjamin Poirier <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-18i40e: remove duplicate device id from PCI tableCarolyn Wyborny1-1/+0
Signed-off-by: Carolyn Wyborny <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-18i40e: mark the value passed to csum_replace_by_diff as __wsumJacob Keller1-2/+3
Fix, or rather, avoid a sparse warning caused by the fact that csum_replace_by_diff expects to receive a __wsum value. Since the calculation appears to work, simply typecast the passed paylen value to __wsum to avoid the warning. This seems pretty fishy since __wsum was obviously annotated as a separate type on purpose, so this throws the entire calculation into question. Since it currently appears to behave as expected, the typecast is probably safe. Change-ID: I4fdc5cddd589abc16098176e8a61127e761488f4 Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-18i40e: Error handling for link eventHarshitha Ramamurthy2-2/+13
There exists an intermittent bug which causes the 'Link Detected' field reported by the 'ethtool <iface>' command to be 'Yes' when in fact, there is no link. This patch fixes the problem by enabling temporary link polling when i40e_get_link_status returns an error. This causes the driver to remember that an admin queue command failed and polls, until the function returns with a success. Change-Id: I64c69b008db4017b8729f3fc27b8f65c8fe2eaa0 Signed-off-by: Harshitha Ramamurthy <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-18i40e: properly convert le16 value to CPU formatJacob Keller1-5/+6
This ensures that the pvid which is stored in __le16 format is converted to the CPU format. This will fix comparison issues on Big Endian platforms. Change-ID: I92c80d1315dc2a0f9f095d5a0c48d461beb052ed Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-18i40e: convert to cpu from le16 to generate switch_id correctlyJacob Keller1-2/+3
On Big Endian platforms we would incorrectly calculate the wrong switch id since we did not properly convert the le16 value into CPU format. Caught by sparse. Change-ID: I69a2f9fa064a0a91691f7d0e6fcc206adceb8e36 Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-18i40e: refactor AQ CMD buffer debug printingAlan Brady1-7/+12
This patch refactors the '%*ph' printk format specifier to instead use the print_hex_dump function, as recommended by the '%*ph' documentation. This produces better/more standardized output. Change-ID: Id56700b4e8abc40ff8c04bc8379e7df04cb4d6fd Signed-off-by: Alan Brady <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-18i40e: Fix Adaptive ITR enablingCarolyn Wyborny1-6/+6
This patch fixes a bug introduced with the addition of the per queue ITR feature support in ethtool. With that addition, there were functions added which converted the ITR settings to binary values. The IS_ENABLED macros that run on those values check whether a bit is set or not and with the value being binary, the bit check always returned ITR disabled which prevents any updating of the ITR rate. This patch fixes the problem by changing the functions to return the current ITR value instead and renaming it to better reflect its function. These functions now provide a value which will be accurately asessed and update the ITR as intended. Change-ID: I14f1d088d052e27f652aaa3113e186415ddea1fc Signed-off-by: Carolyn Wyborny <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-18i40e: remove unnecessary call to i40e_update_link_infoJacob Keller1-1/+0
This call is made just prior to running i40e_link_event. In i40e_link_event, we set hw->phy.get_link_info to true just prior to calling i40e_get_link_status, which conveniently runs i40e_update_link_info for us. Thus, we are running i40e_update_link_info twice, which seems like something we don't need to do... Change-ID: I36467a570f44b7546d218c99e134ff97c2709315 Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-18i40e: enable mc magic pkt wakeup during power downJoshua Hay3-10/+67
This patch adds a call to the mac_address_write admin q function during power down to update the PRTPM_SAH/SAL registers with the MC_MAG_EN bit thus enabling multicast magic packet wakeup. A FW workaround is needed to write the multicast magic wake up enable bit in the PRTPM_SAH register. The FW expects the mac address write admin q cmd to be called first with one of the WRITE_TYPE_LAA flags and then with the multicast relevant flags. *Note: This solution only works for X722 devices currently. A PFR will clear the previously mentioned bit by default, but X722 has support for a WOL_PRESERVE_ON_PFR flag which prevents the bit from being cleared. Once other devices support this flag, this solution should work as well. Change-ID: I51bd5b8535bd9051c2676e27c999c1657f786827 Signed-off-by: Joshua Hay <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-18i40e: fix disable overflow promiscuous modeAlan Brady1-5/+7
There exists a bug in which the driver is unable to exit overflow promiscuous mode after having added "too many" mac filters. It is expected that after triggering overflow promiscuous, removing the failed/extra filters should then disable overflow promiscuous mode. The bug exists because we were intentionally skipping the sync_vsi_filter path in cases where we were removing failed filters since they shouldn't have been added to the firmware in the first place, however we still need to go through the sync_vsi_filter code path to determine whether or not it is ok to exit overflow promiscuous mode. This patch fixes the bug by making sure we go through the sync_vsi_filter path in cases of failed filters. Change-ID: I634d249ca3e5fa50729553137c295e73e7722143 Signed-off-by: Alan Brady <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e: Save more link abilities when using ethtoolHenry Tieman1-0/+3
Ethtool support needs to save more PHY information. The added information includes FEC capabilities and 25G link types. Without this change it is possible to lose 25G or FEC settings by using ethtool. Change-ID: Ie42255b1e901ffbf9583b8c46466a54894114280 Signed-off-by: Henry Tieman <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e: avoid race condition when sending filters to firmware for additionJacob Keller2-51/+112
Refactor how we add new filters to firmware to avoid a race condition that can occur due to removing filters from the hash temporarily. To understand the race condition, suppose that you have a number of MAC filters, but have not yet added any VLANs. Now, add two VLANs in rapid succession. A possible resulting flow would look something like the following: (1) lock hash for add VLAN (2) add the new MAC/VLAN combos for each current MAC filter (3) unlock hash (4) lock hash for filter sync (5) notice that we have a VLAN, so prepare to update all MAC filters with VLAN=-1 to be VLAN=0. (6) move NEW and REMOVE filters to temporary list (7) unlock hash (8) lock hash for add VLAN (9) add new MAC/VLAN combos. Notice that no MAC filters are currently in the hash list, so we don't add any VLANs <--- BUG! (10) unlock hash (11) sync the temporary lists to firmware (12) lock hash for post-sync (13) move the temporary elements back to the main list .... Because we take filters out of the main hash into temporary lists, we introduce a narrow window where it is possible that other callers to the list will not see some of the filters which were previously added but have not yet been finalized. This results in sometimes dropping VLAN additions, and could also result in failing to add a MAC address on the newly added VLAN. One obvious way to avoid this race condition would be to lock the entire firmware process. Unfortunately this does not work because adminq firmware commands take a mutex which results in a sleep while atomic BUG(). So, we can't use the simplest approach. An alternative approach is to simply not remove the filters from the hash list while adding. Instead, add an i40e_new_mac_filter structure which we will use to track added filters. This avoids the need to remove the filter from the hash list. We'll store a pointer to the original i40e_mac_filter, along with our own copy of the state. We won't update the state directly, so as to avoid race with other code that may modify the state while under the lock. We are safe to read f->macaddr and f->vlan since these only change in two locations. The first is on filter creation, which must have already occurred. The second is inside i40e_correct_vlan_filters which was previously run after creation of this object and can't be run again until after. Thus, we should be safe to read the MAC address and VLAN while outside the lock. We also aren't going to run into a use-after-free issue because the only place where we free filters is when they are marked FAILED or when we remove them inside the sync subtask. Since the subtask has its own critical flag to prevent duplicate runs, we know this won't happen. We also know that the only location to transition a filter from NEW to FAILED is inside the subtask also, so we aren't worried about that either. Use the wrapper i40e_new_mac_filter for additions, and once we've finalized the addition to firmware, we will update the filter state inside a lock, and then free the wrapper structure. In order to avoid a possible race condition with filter deletion, we won't update the original filter state unless it is still I40E_FILTER_NEW when we finish the firmware sync. This approach is more complex, but avoids race conditions related to filters being temporarily removed from the list. We do not need the same behavior for deletion because we always unconditionally removed the filters from the list regardless of the firmware status. Change-Id: I14b74bc2301f8e69433fbe77ebca532db20c5317 Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e: allow i40e_update_filter_state to skip broadcast filtersJacob Keller1-8/+29
Fix a bug where we modified the mac_filter_hash while outside a lock, when handling addition of broadcast filters. Normally, we add filters to firmware by batching the additions into lists and issuing 1 update for every few filters. Broadcast filters are handled differently, by instead setting the broadcast promiscuous mode flags. In order to make sure the 1<->1 mapping of filters in our addition array lined up with filters in the hlist tmp_add_list, we had to remove the filter and move it back to the main hash. However, we didn't do this under lock, which could cause consistency problems for the list. Fix this by updating i40e_update_filter_state logic so that it knows to avoid broadcast filters. This ensures that we don't have to remove the filter separately, and can put it back using the normal flow. Change-ID: Id288fade80b3e3a9a54b68cc249188cb95147518 Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e: don't warn every time we clear an Rx timestamp registerJacob Keller1-5/+16
The intent of this message was to indicate to a user that we might have missed a timestamp event for a valid packet. The original method of detecting the missed events relied on waiting until all 4 registers were filled. A recent commit d55458c0cd7a5 ("i40e: replace PTP Rx timestamp hang logic") replaced this logic with much better detection scheme that could detect a stalled Rx timestamp register even when other registers were still functional. The new logic means that a message will be displayed almost as soon as a timestamp for a dropped frame occurs. This new logic highlights that the hardware will attempt timestamp for frames which it later decides to drop. The most prominent example is when a multicast PTP frame is received on a multicast address that we are not subscribed to. Because the hardware initiates the Rx timestamp as soon as possible, it will latch an RXTIME register, but then drop the packet. This results in users being confused by the message as they are not expecting to see dropped timestamp messages unless their application also indicates that timestamps were missing. Resolve this by reducing the severity and frequency of the displayed message. We now only print the message if 3 or 4 of the RXTIME registers are stalled and get cleared within the same watchdog event. This ensures that the common case does not constantly display the message. Additionally, since the message is likely not as meaningful to most users, reduce the message to a dev_dbg instead of a dev_warn. Users can still get a count of the number of timestamps dropped by reading the ethtool statistics value, if necessary. Change-ID: I35494442226a444c418dfb4f91a3070d06c8435c Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e: Save link FEC info from link up eventHenry Tieman3-2/+22
Store the FEC status bits from the link up event into the hw_link_info structure. Change-ID: I9a7b256f6dfb0dce89c2f503075d0d383526832e Signed-off-by: Henry Tieman <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e: Add bus number info to i40e_bus_info structSudheer Mogilappagari4-13/+17
Currently i40e_bus_info has PCI device and function info only and log messages print device number as bus number. Added field to provide bus number info and modified log statements to print bus, device and function information. Change-ID: I811617cee2714cc0d6bade8d369f57040990756f Signed-off-by: Sudheer Mogilappagari <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e: Clean up dead codeMitch Williams1-10/+3
The function i40e_client_prepare() can never return an error. So make it void and quit checking its return value. Change-ID: I9ff311e2324dde329eb68648efb2c94aaff856db Signed-off-by: Mitch Williams <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e/i40evf : Changed version from 1.6.25 to 1.6.27Bimmy Pujari1-1/+1
Signed-off-by: Bimmy Pujari <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e: update comment explaining where FDIR buffers are freedJacob Keller1-1/+6
The original comment implies that the only location where the raw_packet buffer will be freed is in i40e_clean_tx_ring() which is incorrect. In fact this isn't even the normal case. Update the comment explaining where the memory is freed. Change-ID: Ie0defc35ed1c3af183f81fdc60b6d783707a5595 Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e/i40evf: eliminate i40e_pull_tail()Scott Peterson1-76/+93
Reorganize the i40e_pull_tail() logic, doing it in i40e_add_rx_frag() where it's cheaper. The igb driver does this the same way. Also renames i40e_page_is_reserved() to reflect what it actually tests. Change-ID: Icd9cc507aae1fcdc02308b3a09034111b4c24071 Signed-off-by: Scott Peterson <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e/i40evf: Moves skb from i40e_rx_buffer to i40e_ringScott Peterson2-17/+23
This patch reduces the size of struct i40e_rx_buffer by one pointer, and makes the i40e driver a little more consistent with the igb driver in terms of packets that span buffers. We do this by moving the skb field from struct i40e_rx_buffer to struct i40e_ring. We pass the skb we already have (or NULL if we don't) to i40e_fetch_rx_buffer(), which skips the skb allocation if we already have one for this packet. Change-ID: I4ad48a531844494ba0c5d8e1a62209a057f661b0 Signed-off-by: Scott Peterson <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e/i40evf: Limit DMA sync of RX buffers to actual packet sizeScott Peterson1-7/+9
On packet RX, we perform a DMA sync for CPU before passing the packet up. Here we limit that sync to the actual length of the incoming packet, rather than always syncing the entire buffer. Change-ID: I626aaf6c37275a8ce9e81efcaa773f327b331487 Signed-off-by: Scott Peterson <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-11i40e: don't check params until after checking for client instanceJacob Keller1-2/+2
We can avoid the minor bit of work by calling check params after we check for the client instance, since we're about to return early in cases where we do not have a client. Change-ID: I56f8ea2ba48d4f571fa331c9ace50819a022fa1c Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-02i40e: add interrupt rate limit verbosityAlan Brady1-3/+10
Due to the resolution of the register controlling interrupt rate limiting, setting certain values for the interrupt rate limit make it appear as though the limiting is not completely accurate. The problem is that the interrupt rate limit is getting rounded down to the nearest multiple of 4. This patch fixes the problem by adding some feedback to the user as to the actual interrupt rate limit being used when it differs from the requested limit. Without this patch setting interrupt rate limits may appear to behave inaccurately. Change-ID: I3093cf3f2d437d35a4c4f4bb5af5ce1b85ab21b7 Signed-off-by: Alan Brady <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-02i40e: refactor macro INTRL_USEC_TO_REGAlan Brady3-3/+16
This patch refactors the macro INTRL_USEC_TO_REG into a static inline function and fixes a couple subtle bugs caused by the macro. This patch fixes a bug which was caused by passing a bad register value to the firmware. If enabling interrupt rate limiting, a non-zero value for the rate limit must be used. Otherwise the firmware sets the interrupt rate limit to the maximum value. Due to the limited resolution of the register, attempting to set a value of 1, 2, or 3 would be rounded down to 0 and limiting was left enabled, causing unexpected behavior. This patch also fixes a possible bug in which using the macro itself can introduce unintended side-affects because the macro argument is used more than once in the macro definition (e.g. a variable post-increment argument would perform a double increment on the variable). Without this patch, attempting to set interrupt rate limits of 1, 2, or 3 results in unexpected behavior and future use of this macro could cause subtle bugs. Change-Id: I83ac842de0ca9c86761923d6e3a4d7b1b95f2b3f Signed-off-by: Alan Brady <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-02i40e: remove unused functionMitch Williams2-36/+0
After refactoring the client open and close code, this is no longer needed. Remove it. Change-ID: If8e6e32baa354d857c2fd8b2f19404f1786011c4 Signed-off-by: Mitch Williams <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-02i40e: Quick refactor to start moving data off stack and into Tx buffer infoAlexander Duyck1-20/+27
This patch does some quick work to pull some of the data off of the stack and hopefully start storing it in the Tx buffer info section of the Tx ring. Ideally we should be moving away from having to store much of anything on the stack and can just maintain it all in the descriptor rings. Change-ID: I4b4715ea1920e122502482b3f9e56a9a6cb1e9fe Signed-off-by: Alexander Duyck <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-02i40e: remove unnecessary __packedTushar Dave1-2/+2
'struct i40e_dma_mem' defined with 'packed' directive causing kernel unaligned errors on sparc. e.g. i40e: Intel(R) Ethernet Connection XL710 Network Driver - version 1.6.16-k i40e: Copyright (c) 2013 - 2014 Intel Corporation. Kernel unaligned access at TPC[44894c] dma_4v_alloc_coherent+0x1ac/0x300 Kernel unaligned access at TPC[44894c] dma_4v_alloc_coherent+0x1ac/0x300 Kernel unaligned access at TPC[44894c] dma_4v_alloc_coherent+0x1ac/0x300 Kernel unaligned access at TPC[44894c] dma_4v_alloc_coherent+0x1ac/0x300 Kernel unaligned access at TPC[44894c] dma_4v_alloc_coherent+0x1ac/0x300 i40e 0000:03:00.0: fw 5.1.40981 api 1.5 nvm 5.04 0x80002548 0.0.0 This can be fixed with get_unaligned/put_unaligned(). However no reference in driver shows that 'struct i40e_dma_mem' directly shoved into NIC hardware. But instead fields of the struct are being read and used for hardware. Therefore, __packed is unnecessary for 'struct i40e_dma_mem'. In addition, although 'struct i40e_virt_mem' doesn't cause any unaligned access, keeping it packed is unnecessary as well because of aforementioned reason. This change make 'struct i40e_dma_mem' and 'struct i40e_virt_mem' unpacked. Signed-off-by: Tushar Dave <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-02i40e: Deprecating unused macroBimmy Pujari3-17/+3
I40E_MAC_X710 was supposed to be for 10G and I40E_MAC_XL710 was supposed to be for 40G. But function i40e_is_mac_710 sets I40E_MAC_XL710 for all device IDS, I40E_MAC_X710 is not used at all. As there is nothing to compare there is no need for this function. Thus deprecating this extra macro and removing this function entirely and replacing it with a direct check. Change-ID: I7d1769954dccd574a290ac04adb836ebd156730e Signed-off-by: Bimmy Pujari <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-02i40e: when adding or removing MAC filters, correctly handle VLANsJacob Keller2-10/+7
Instead of using i40e_add_filter or i40e_del_filter directly, when adding a MAC address, we should normally be using i40e_add_mac_filter or i40e_del_mac_filter. These functions correctly handle the various cases of VLAN mode or PVID settings. This ensures consistency and avoids the issues that can occur with the recent addition of a WARN_ON() in i40e_sync_vsi_filters. Change-ID: I7fe62db063391fdd1180b2d6a6a3c5ab4307eeee Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-02i40e: avoid O(n^2) loop when deleting all filtersJacob Keller3-2/+3
Use __i40e_del_filter instead of using i40e_del_filter() which will avoid doing an additional search to delete a filter we already have the pointer for. Change-ID: Iea5a7e3cafbf8c682ed9d3b6c69cf5ff53f44daf Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>
2017-02-02i40e: rename i40e_put_mac_in_vlan and i40e_del_mac_all_vlanJacob Keller3-16/+18
These functions purpose is to add a new MAC filter correctly, whether we're using VLANs or not. Their goal is to ensure that all active VLANs get the new MAC filter. Rename them so that their intent is clear. They function correctly regardless of whether we have any active VLANs or only have I40E_VLAN_ANY filters. The new names convey how they function in a more clear manner. Change-ID: Iec1961f968c0223a7132724a74e26a665750b107 Signed-off-by: Jacob Keller <[email protected]> Tested-by: Andrew Bowers <[email protected]> Signed-off-by: Jeff Kirsher <[email protected]>