diff --git a/drivers/hwmon/pmbus/pli1209bc.c b/drivers/hwmon/pmbus/pli1209bc.c
index 2c6c9ec2a652..178e0cdb7887 100644
--- a/drivers/hwmon/pmbus/pli1209bc.c
+++ b/drivers/hwmon/pmbus/pli1209bc.c
@@ -54,30 +54,6 @@ static int pli1209bc_read_word_data(struct i2c_client *client, int page,
}
}
-static int pli1209bc_write_byte(struct i2c_client *client, int page, u8 reg)
-{
- int ret;
-
- switch (reg) {
- case PMBUS_CLEAR_FAULTS:
- ret = pmbus_write_byte(client, page, reg);
- /*
- * PLI1209 takes 230 usec to execute the CLEAR_FAULTS command.
- * During that time it's busy and NACKs all requests on the
- * SMBUS interface. It also NACKs reads on PMBUS_STATUS_BYTE
- * making it impossible to poll the BUSY flag.
- *
- * Just wait for not BUSY unconditionally.
- */
- usleep_range(250, 300);
- break;
- default:
- ret = -ENODATA;
- break;
- }
- return ret;
-}
-
#if IS_ENABLED(CONFIG_SENSORS_PLI1209BC_REGULATOR)
static const struct regulator_desc pli1209bc_reg_desc = {
.name = "vout2",
@@ -127,7 +103,7 @@ static struct pmbus_driver_info pli1209bc_info = {
| PMBUS_HAVE_TEMP | PMBUS_HAVE_STATUS_TEMP
| PMBUS_HAVE_STATUS_IOUT | PMBUS_HAVE_STATUS_INPUT,
.read_word_data = pli1209bc_read_word_data,
- .write_byte = pli1209bc_write_byte,
+ .write_delay = 250,
#if IS_ENABLED(CONFIG_SENSORS_PLI1209BC_REGULATOR)
.num_regulators = 1,
.reg_desc = &pli1209bc_reg_desc,