@@ -225,8 +225,6 @@ pwm[1-*]_auto_point[1-*]_temp_hyst
to PWM output channels.
RW
-OR
-
temp[1-*]_auto_point[1-*]_pwm
temp[1-*]_auto_point[1-*]_temp
temp[1-*]_auto_point[1-*]_temp_hyst
@@ -235,6 +233,15 @@ temp[1-*]_auto_point[1-*]_temp_hyst
to temperature channels.
RW
+There is a third case where trip points are associated to both PWM output
+channels and temperature channels: the PWM values are associated to PWM
+output channels while the temperature values are associated to temperature
+channels. In that case, the result is determined by the mapping between
+temperature inputs and PWM outputs. When several temperature inputs are
+mapped to a given PWM output, this leads to several candidate PWM values.
+The actual result is up to the chip, but in general the highest candidate
+value (fastest fan speed) wins.
+
****************
* Temperatures *
@@ -353,10 +360,20 @@ power[1-*]_average Average power use
Unit: microWatt
RO
-power[1-*]_average_interval Power use averaging interval
+power[1-*]_average_interval Power use averaging interval. A poll
+ notification is sent to this file if the
+ hardware changes the averaging interval.
Unit: milliseconds
RW
+power[1-*]_average_interval_max Maximum power use averaging interval
+ Unit: milliseconds
+ RO
+
+power[1-*]_average_interval_min Minimum power use averaging interval
+ Unit: milliseconds
+ RO
+
power[1-*]_average_highest Historical average maximum power use
Unit: microWatt
RO
@@ -365,6 +382,18 @@ power[1-*]_average_lowest Historical average minimum power use
Unit: microWatt
RO
+power[1-*]_average_max A poll notification is sent to
+ power[1-*]_average when power use
+ rises above this value.
+ Unit: microWatt
+ RW
+
+power[1-*]_average_min A poll notification is sent to
+ power[1-*]_average when power use
+ sinks below this value.
+ Unit: microWatt
+ RW
+
power[1-*]_input Instantaneous power use
Unit: microWatt
RO
@@ -381,6 +410,39 @@ power[1-*]_reset_history Reset input_highest, input_lowest,
average_highest and average_lowest.
WO
+power[1-*]_accuracy Accuracy of the power meter.
+ Unit: Percent
+ RO
+
+power[1-*]_alarm 1 if the system is drawing more power than the
+ cap allows; 0 otherwise. A poll notification is
+ sent to this file when the power use exceeds the
+ cap. This file only appears if the cap is known
+ to be enforced by hardware.
+ RO
+
+power[1-*]_cap If power use rises above this limit, the
+ system should take action to reduce power use.
+ A poll notification is sent to this file if the
+ cap is changed by the hardware. The *_cap
+ files only appear if the cap is known to be
+ enforced by hardware.
+ Unit: microWatt
+ RW
+
+power[1-*]_cap_hyst Margin of hysteresis built around capping and
+ notification.
+ Unit: microWatt
+ RW
+
+power[1-*]_cap_max Maximum cap that can be set.
+ Unit: microWatt
+ RO
+
+power[1-*]_cap_min Minimum cap that can be set.
+ Unit: microWatt
+ RO
+
**********