authorThierry Reding <[email protected]>2020-08-06 17:42:45 +0200
committerThierry Reding <[email protected]>2020-08-27 17:36:46 +0200
commit562da8b494c4e2f72d0789a03e6ccd9dc14d3f25 (patch)
treef6c127574aaa6d8017c77ee73c48a721d545b7ba /tools/perf/scripts/python/exported-sql-viewer.py
parent0cc6ba3ce87c2845689599a87ee993d1aec9ca89 (diff)
arm64: tegra: Use valid PWM period for VDD_GPU on Tegra210
The PWM on Tegra210 can run at a maximum frequency of 48 MHz and cannot reach the minimum period is 5334 ns. The currently configured period of 4880 ns is not within the valid range, so set it to 8000 ns. This value was taken from the downstream DTS files and seems to work fine. Signed-off-by: Thierry Reding <[email protected]>