authorSandeep Singh <[email protected]>2018-11-09 17:21:19 +0200
committerGreg Kroah-Hartman <[email protected]>2018-11-09 08:31:08 -0800
commitd9193efba84fe4c4aa22a569fade5e6ca971f8af (patch)
tree22c14f49702610856ae1f115aebf837d11504b64 /tools/perf/scripts/python/export-to-postgresql.py
parent1245374e9b8340fc255fd51b2015173a83050d03 (diff)
xhci: Add check for invalid byte size error when UAS devices are connected.
Observed "TRB completion code (27)" error which corresponds to Stopped - Length Invalid error(xhci spec section 4.17.4) while connecting USB to SATA bridge. Looks like this case was not considered when the following patch[1] was committed. Hence adding this new check which can prevent the invalid byte size error. [1] ade2e3a xhci: handle transfer events without TRB pointer Cc: <[email protected]> Signed-off-by: Sandeep Singh <[email protected]> cc: Nehal Shah <[email protected]> cc: Shyam Sundar S K <[email protected]> Signed-off-by: Mathias Nyman <[email protected]> Signed-off-by: Greg Kroah-Hartman <[email protected]>