authorMatti Vaittinen <[email protected]>2021-06-03 08:40:28 +0300
committerMark Brown <[email protected]>2021-06-21 13:08:27 +0100
commit673e851b7da81256e73fb738c550ec39bac1c9ff (patch)
treee51fe6fc0635e25675e429ef2d050ea35fe2e40b /tools/perf/scripts/python/export-to-postgresql.py
parent8124c8a6b35386f73523d27eacb71b5364a68c4c (diff)
regulator: Add protection limit properties
Support specifying protection/error/warning limits for regulator over current, over temperature and over/under voltage. Most of the PMICs support only "protection" feature but few setups do also support error/warning level indications. On many ICs most of the protection limits can't actually be set. But for example the ampere limit for over-current protection on ROHM BD9576 can be configured - or feature can be completely disabled. Provide limit setting for all protections/errors for the sake of the completeness and do that using own properties for all so that not all users would need to set all levels when only one or few are supported. Signed-off-by: Matti Vaittinen <[email protected]> Reviewed-by: Rob Herring <[email protected]> Link: https://lore.kernel.org/r/ae2c6056d5ed1334912d27e736d23c9151065433.1622628333.git.matti.vaittinen@fi.rohmeurope.com Signed-off-by: Mark Brown <[email protected]>