authorYH Huang <[email protected]>2016-04-06 10:32:25 +0800
committerSebastian Reichel <[email protected]>2016-04-10 17:22:35 +0200
commit4a99fa06a8ca27a5187636e630568658000af575 (patch)
treea13f148fce1554569f1302301e29e4162046ae56 /tools/perf/scripts/python/export-to-postgresql.py
parentb9223da41794030a5dfd5106c34ed1b98255e2ae (diff)
sbs-battery: fix power status when battery charging near dry
POWER_SUPPLY_STATUS_NOT_CHARGING is used for AC connected, but battery not charging (e.g. because battery temperature is out of acceptable range). When battery is charging near dry and BATTERY_FULL_DISCHARGED is set, it is wrong to set as POWER_SUPPLY_STATUS_NOT_CHARGING. Just use BATTERY_DISCHARGING to decide the power supply status is discharging or charging. Signed-off-by: YH Huang <[email protected]> Reviewed-by: Daniel Kurtz <[email protected]> Signed-off-by: Sebastian Reichel <[email protected]>