aboutsummaryrefslogtreecommitdiff
path: root/tools/perf/scripts/python/call-graph-from-sql.py
diff options
context:
space:
mode:
authorMartyn Welch <[email protected]>2017-10-19 16:51:44 +0100
committerGuenter Roeck <[email protected]>2017-10-21 09:03:29 -0700
commitb16918a5fd87983d421a7e2241a1314e877c4ea2 (patch)
treededd75860f16877654114ed7cf3784b1514ce1bd /tools/perf/scripts/python/call-graph-from-sql.py
parent8a5776a5f49812d29fe4b2d0a2d71675c3facf3f (diff)
hwmon: (da9052) Increase sample rate when using TSI
The TSI channel, which is usually used for touchscreen support, but can be used as 4 general purpose ADCs. When used as a touchscreen interface the touchscreen driver switches the device into 1ms sampling mode (rather than the default 10ms economy mode) as recommended by the manufacturer. When using the TSI channels as a general purpose ADC we are currently not doing this and testing suggests that this can result in ADC timeouts: [ 5827.198289] da9052 spi2.0: timeout waiting for ADC conversion interrupt [ 5827.728293] da9052 spi2.0: timeout waiting for ADC conversion interrupt [ 5993.808335] da9052 spi2.0: timeout waiting for ADC conversion interrupt [ 5994.328441] da9052 spi2.0: timeout waiting for ADC conversion interrupt [ 5994.848291] da9052 spi2.0: timeout waiting for ADC conversion interrupt Switching to the 1ms timing resolves this issue. Fixes: 4f16cab19a3d5 ("hwmon: da9052: Add support for TSI channel") Signed-off-by: Martyn Welch <[email protected]> Acked-by: Steve Twiss <[email protected]> Signed-off-by: Guenter Roeck <[email protected]>
Diffstat (limited to 'tools/perf/scripts/python/call-graph-from-sql.py')
0 files changed, 0 insertions, 0 deletions