17e02586ed
and fix all in-tree references. Architecture-specific documentation is being moved into Documentation/arch/ as a way of cleaning up the top-level documentation directory and making the docs hierarchy more closely match the source hierarchy. Signed-off-by: Costa Shulyupin <costa.shul@redhat.com> Acked-by: Michael Ellerman <mpe@ellerman.id.au> Signed-off-by: Jonathan Corbet <corbet@lwn.net> Link: https://lore.kernel.org/r/20230826165737.2101199-1-costa.shul@redhat.com
302 lines
14 KiB
ReStructuredText
302 lines
14 KiB
ReStructuredText
.. SPDX-License-Identifier: GPL-2.0
|
|
|
|
===========================
|
|
Hypercall Op-codes (hcalls)
|
|
===========================
|
|
|
|
Overview
|
|
=========
|
|
|
|
Virtualization on 64-bit Power Book3S Platforms is based on the PAPR
|
|
specification [1]_ which describes the run-time environment for a guest
|
|
operating system and how it should interact with the hypervisor for
|
|
privileged operations. Currently there are two PAPR compliant hypervisors:
|
|
|
|
- **IBM PowerVM (PHYP)**: IBM's proprietary hypervisor that supports AIX,
|
|
IBM-i and Linux as supported guests (termed as Logical Partitions
|
|
or LPARS). It supports the full PAPR specification.
|
|
|
|
- **Qemu/KVM**: Supports PPC64 linux guests running on a PPC64 linux host.
|
|
Though it only implements a subset of PAPR specification called LoPAPR [2]_.
|
|
|
|
On PPC64 arch a guest kernel running on top of a PAPR hypervisor is called
|
|
a *pSeries guest*. A pseries guest runs in a supervisor mode (HV=0) and must
|
|
issue hypercalls to the hypervisor whenever it needs to perform an action
|
|
that is hypervisor privileged [3]_ or for other services managed by the
|
|
hypervisor.
|
|
|
|
Hence a Hypercall (hcall) is essentially a request by the pseries guest
|
|
asking hypervisor to perform a privileged operation on behalf of the guest. The
|
|
guest issues a with necessary input operands. The hypervisor after performing
|
|
the privilege operation returns a status code and output operands back to the
|
|
guest.
|
|
|
|
HCALL ABI
|
|
=========
|
|
The ABI specification for a hcall between a pseries guest and PAPR hypervisor
|
|
is covered in section 14.5.3 of ref [2]_. Switch to the Hypervisor context is
|
|
done via the instruction **HVCS** that expects the Opcode for hcall is set in *r3*
|
|
and any in-arguments for the hcall are provided in registers *r4-r12*. If values
|
|
have to be passed through a memory buffer, the data stored in that buffer should be
|
|
in Big-endian byte order.
|
|
|
|
Once control returns back to the guest after hypervisor has serviced the
|
|
'HVCS' instruction the return value of the hcall is available in *r3* and any
|
|
out values are returned in registers *r4-r12*. Again like in case of in-arguments,
|
|
any out values stored in a memory buffer will be in Big-endian byte order.
|
|
|
|
Powerpc arch code provides convenient wrappers named **plpar_hcall_xxx** defined
|
|
in a arch specific header [4]_ to issue hcalls from the linux kernel
|
|
running as pseries guest.
|
|
|
|
Register Conventions
|
|
====================
|
|
|
|
Any hcall should follow same register convention as described in section 2.2.1.1
|
|
of "64-Bit ELF V2 ABI Specification: Power Architecture"[5]_. Table below
|
|
summarizes these conventions:
|
|
|
|
+----------+----------+-------------------------------------------+
|
|
| Register |Volatile | Purpose |
|
|
| Range |(Y/N) | |
|
|
+==========+==========+===========================================+
|
|
| r0 | Y | Optional-usage |
|
|
+----------+----------+-------------------------------------------+
|
|
| r1 | N | Stack Pointer |
|
|
+----------+----------+-------------------------------------------+
|
|
| r2 | N | TOC |
|
|
+----------+----------+-------------------------------------------+
|
|
| r3 | Y | hcall opcode/return value |
|
|
+----------+----------+-------------------------------------------+
|
|
| r4-r10 | Y | in and out values |
|
|
+----------+----------+-------------------------------------------+
|
|
| r11 | Y | Optional-usage/Environmental pointer |
|
|
+----------+----------+-------------------------------------------+
|
|
| r12 | Y | Optional-usage/Function entry address at |
|
|
| | | global entry point |
|
|
+----------+----------+-------------------------------------------+
|
|
| r13 | N | Thread-Pointer |
|
|
+----------+----------+-------------------------------------------+
|
|
| r14-r31 | N | Local Variables |
|
|
+----------+----------+-------------------------------------------+
|
|
| LR | Y | Link Register |
|
|
+----------+----------+-------------------------------------------+
|
|
| CTR | Y | Loop Counter |
|
|
+----------+----------+-------------------------------------------+
|
|
| XER | Y | Fixed-point exception register. |
|
|
+----------+----------+-------------------------------------------+
|
|
| CR0-1 | Y | Condition register fields. |
|
|
+----------+----------+-------------------------------------------+
|
|
| CR2-4 | N | Condition register fields. |
|
|
+----------+----------+-------------------------------------------+
|
|
| CR5-7 | Y | Condition register fields. |
|
|
+----------+----------+-------------------------------------------+
|
|
| Others | N | |
|
|
+----------+----------+-------------------------------------------+
|
|
|
|
DRC & DRC Indexes
|
|
=================
|
|
::
|
|
|
|
DR1 Guest
|
|
+--+ +------------+ +---------+
|
|
| | <----> | | | User |
|
|
+--+ DRC1 | | DRC | Space |
|
|
| PAPR | Index +---------+
|
|
DR2 | Hypervisor | | |
|
|
+--+ | | <-----> | Kernel |
|
|
| | <----> | | Hcall | |
|
|
+--+ DRC2 +------------+ +---------+
|
|
|
|
PAPR hypervisor terms shared hardware resources like PCI devices, NVDIMMs etc
|
|
available for use by LPARs as Dynamic Resource (DR). When a DR is allocated to
|
|
an LPAR, PHYP creates a data-structure called Dynamic Resource Connector (DRC)
|
|
to manage LPAR access. An LPAR refers to a DRC via an opaque 32-bit number
|
|
called DRC-Index. The DRC-index value is provided to the LPAR via device-tree
|
|
where its present as an attribute in the device tree node associated with the
|
|
DR.
|
|
|
|
HCALL Return-values
|
|
===================
|
|
|
|
After servicing the hcall, hypervisor sets the return-value in *r3* indicating
|
|
success or failure of the hcall. In case of a failure an error code indicates
|
|
the cause for error. These codes are defined and documented in arch specific
|
|
header [4]_.
|
|
|
|
In some cases a hcall can potentially take a long time and need to be issued
|
|
multiple times in order to be completely serviced. These hcalls will usually
|
|
accept an opaque value *continue-token* within there argument list and a
|
|
return value of *H_CONTINUE* indicates that hypervisor hasn't still finished
|
|
servicing the hcall yet.
|
|
|
|
To make such hcalls the guest need to set *continue-token == 0* for the
|
|
initial call and use the hypervisor returned value of *continue-token*
|
|
for each subsequent hcall until hypervisor returns a non *H_CONTINUE*
|
|
return value.
|
|
|
|
HCALL Op-codes
|
|
==============
|
|
|
|
Below is a partial list of HCALLs that are supported by PHYP. For the
|
|
corresponding opcode values please look into the arch specific header [4]_:
|
|
|
|
**H_SCM_READ_METADATA**
|
|
|
|
| Input: *drcIndex, offset, buffer-address, numBytesToRead*
|
|
| Out: *numBytesRead*
|
|
| Return Value: *H_Success, H_Parameter, H_P2, H_P3, H_Hardware*
|
|
|
|
Given a DRC Index of an NVDIMM, read N-bytes from the metadata area
|
|
associated with it, at a specified offset and copy it to provided buffer.
|
|
The metadata area stores configuration information such as label information,
|
|
bad-blocks etc. The metadata area is located out-of-band of NVDIMM storage
|
|
area hence a separate access semantics is provided.
|
|
|
|
**H_SCM_WRITE_METADATA**
|
|
|
|
| Input: *drcIndex, offset, data, numBytesToWrite*
|
|
| Out: *None*
|
|
| Return Value: *H_Success, H_Parameter, H_P2, H_P4, H_Hardware*
|
|
|
|
Given a DRC Index of an NVDIMM, write N-bytes to the metadata area
|
|
associated with it, at the specified offset and from the provided buffer.
|
|
|
|
**H_SCM_BIND_MEM**
|
|
|
|
| Input: *drcIndex, startingScmBlockIndex, numScmBlocksToBind,*
|
|
| *targetLogicalMemoryAddress, continue-token*
|
|
| Out: *continue-token, targetLogicalMemoryAddress, numScmBlocksToBound*
|
|
| Return Value: *H_Success, H_Parameter, H_P2, H_P3, H_P4, H_Overlap,*
|
|
| *H_Too_Big, H_P5, H_Busy*
|
|
|
|
Given a DRC-Index of an NVDIMM, map a continuous SCM blocks range
|
|
*(startingScmBlockIndex, startingScmBlockIndex+numScmBlocksToBind)* to the guest
|
|
at *targetLogicalMemoryAddress* within guest physical address space. In
|
|
case *targetLogicalMemoryAddress == 0xFFFFFFFF_FFFFFFFF* then hypervisor
|
|
assigns a target address to the guest. The HCALL can fail if the Guest has
|
|
an active PTE entry to the SCM block being bound.
|
|
|
|
**H_SCM_UNBIND_MEM**
|
|
| Input: drcIndex, startingScmLogicalMemoryAddress, numScmBlocksToUnbind
|
|
| Out: numScmBlocksUnbound
|
|
| Return Value: *H_Success, H_Parameter, H_P2, H_P3, H_In_Use, H_Overlap,*
|
|
| *H_Busy, H_LongBusyOrder1mSec, H_LongBusyOrder10mSec*
|
|
|
|
Given a DRC-Index of an NVDimm, unmap *numScmBlocksToUnbind* SCM blocks starting
|
|
at *startingScmLogicalMemoryAddress* from guest physical address space. The
|
|
HCALL can fail if the Guest has an active PTE entry to the SCM block being
|
|
unbound.
|
|
|
|
**H_SCM_QUERY_BLOCK_MEM_BINDING**
|
|
|
|
| Input: *drcIndex, scmBlockIndex*
|
|
| Out: *Guest-Physical-Address*
|
|
| Return Value: *H_Success, H_Parameter, H_P2, H_NotFound*
|
|
|
|
Given a DRC-Index and an SCM Block index return the guest physical address to
|
|
which the SCM block is mapped to.
|
|
|
|
**H_SCM_QUERY_LOGICAL_MEM_BINDING**
|
|
|
|
| Input: *Guest-Physical-Address*
|
|
| Out: *drcIndex, scmBlockIndex*
|
|
| Return Value: *H_Success, H_Parameter, H_P2, H_NotFound*
|
|
|
|
Given a guest physical address return which DRC Index and SCM block is mapped
|
|
to that address.
|
|
|
|
**H_SCM_UNBIND_ALL**
|
|
|
|
| Input: *scmTargetScope, drcIndex*
|
|
| Out: *None*
|
|
| Return Value: *H_Success, H_Parameter, H_P2, H_P3, H_In_Use, H_Busy,*
|
|
| *H_LongBusyOrder1mSec, H_LongBusyOrder10mSec*
|
|
|
|
Depending on the Target scope unmap all SCM blocks belonging to all NVDIMMs
|
|
or all SCM blocks belonging to a single NVDIMM identified by its drcIndex
|
|
from the LPAR memory.
|
|
|
|
**H_SCM_HEALTH**
|
|
|
|
| Input: drcIndex
|
|
| Out: *health-bitmap (r4), health-bit-valid-bitmap (r5)*
|
|
| Return Value: *H_Success, H_Parameter, H_Hardware*
|
|
|
|
Given a DRC Index return the info on predictive failure and overall health of
|
|
the PMEM device. The asserted bits in the health-bitmap indicate one or more states
|
|
(described in table below) of the PMEM device and health-bit-valid-bitmap indicate
|
|
which bits in health-bitmap are valid. The bits are reported in
|
|
reverse bit ordering for example a value of 0xC400000000000000
|
|
indicates bits 0, 1, and 5 are valid.
|
|
|
|
Health Bitmap Flags:
|
|
|
|
+------+-----------------------------------------------------------------------+
|
|
| Bit | Definition |
|
|
+======+=======================================================================+
|
|
| 00 | PMEM device is unable to persist memory contents. |
|
|
| | If the system is powered down, nothing will be saved. |
|
|
+------+-----------------------------------------------------------------------+
|
|
| 01 | PMEM device failed to persist memory contents. Either contents were |
|
|
| | not saved successfully on power down or were not restored properly on |
|
|
| | power up. |
|
|
+------+-----------------------------------------------------------------------+
|
|
| 02 | PMEM device contents are persisted from previous IPL. The data from |
|
|
| | the last boot were successfully restored. |
|
|
+------+-----------------------------------------------------------------------+
|
|
| 03 | PMEM device contents are not persisted from previous IPL. There was no|
|
|
| | data to restore from the last boot. |
|
|
+------+-----------------------------------------------------------------------+
|
|
| 04 | PMEM device memory life remaining is critically low |
|
|
+------+-----------------------------------------------------------------------+
|
|
| 05 | PMEM device will be garded off next IPL due to failure |
|
|
+------+-----------------------------------------------------------------------+
|
|
| 06 | PMEM device contents cannot persist due to current platform health |
|
|
| | status. A hardware failure may prevent data from being saved or |
|
|
| | restored. |
|
|
+------+-----------------------------------------------------------------------+
|
|
| 07 | PMEM device is unable to persist memory contents in certain conditions|
|
|
+------+-----------------------------------------------------------------------+
|
|
| 08 | PMEM device is encrypted |
|
|
+------+-----------------------------------------------------------------------+
|
|
| 09 | PMEM device has successfully completed a requested erase or secure |
|
|
| | erase procedure. |
|
|
+------+-----------------------------------------------------------------------+
|
|
|10:63 | Reserved / Unused |
|
|
+------+-----------------------------------------------------------------------+
|
|
|
|
**H_SCM_PERFORMANCE_STATS**
|
|
|
|
| Input: drcIndex, resultBuffer Addr
|
|
| Out: None
|
|
| Return Value: *H_Success, H_Parameter, H_Unsupported, H_Hardware, H_Authority, H_Privilege*
|
|
|
|
Given a DRC Index collect the performance statistics for NVDIMM and copy them
|
|
to the resultBuffer.
|
|
|
|
**H_SCM_FLUSH**
|
|
|
|
| Input: *drcIndex, continue-token*
|
|
| Out: *continue-token*
|
|
| Return Value: *H_SUCCESS, H_Parameter, H_P2, H_BUSY*
|
|
|
|
Given a DRC Index Flush the data to backend NVDIMM device.
|
|
|
|
The hcall returns H_BUSY when the flush takes longer time and the hcall needs
|
|
to be issued multiple times in order to be completely serviced. The
|
|
*continue-token* from the output to be passed in the argument list of
|
|
subsequent hcalls to the hypervisor until the hcall is completely serviced
|
|
at which point H_SUCCESS or other error is returned by the hypervisor.
|
|
|
|
References
|
|
==========
|
|
.. [1] "Power Architecture Platform Reference"
|
|
https://en.wikipedia.org/wiki/Power_Architecture_Platform_Reference
|
|
.. [2] "Linux on Power Architecture Platform Reference"
|
|
https://members.openpowerfoundation.org/document/dl/469
|
|
.. [3] "Definitions and Notation" Book III-Section 14.5.3
|
|
https://openpowerfoundation.org/?resource_lib=power-isa-version-3-0
|
|
.. [4] arch/powerpc/include/asm/hvcall.h
|
|
.. [5] "64-Bit ELF V2 ABI Specification: Power Architecture"
|
|
https://openpowerfoundation.org/?resource_lib=64-bit-elf-v2-abi-specification-power-architecture
|